Sigma Plus
Assembly /Assembly without/with masterkey wavers
9
Preparation of assembly superstructure
For each Sigma Plus contract you receive a sheet with tables of assembly super-
structures of the cylinders. If positions of core and body pins are not stated in the ta-
ble ex works please enter the pins in the table.
The following shall apply:
The
FB body pins
may only be assembled
at the first five positions, maximally 2
at each side of the cylinder.
FB body pins
are assemble to the positions with the
lowest values
. In case of su-
perstructures (master key system), the lowest value including the superstructure is
considered.
Only N pins are available as
core pins
for the lengths of 0, 1, 2, 3, and for the
lengths 4, 5, 6, 7 only AB pins are available. There is no restriction of the positions
for core pins. The core pins are applied at
positions P1 – P6
depending on their
lengths.
Assembly without masterkey wafers
Body pins
4
5
1
2
3
5
FB
FB
P1
P2
P3
P4
P5
P6
4
5
1
2
3
5
N
N
FB
FB
N
N
P1
P2
P3
P4
P5
P6
1.) At first the
two
FB-body pins
are inserted at
the
positions
P1 – P5
with
the lowest val-
ues
.
(here: position P3=value 1 and P4=value 2)
2.)
N-pins
are inserted at the
remaining posi-
tions
.