Assembling the device
58
Carrying out standard configuration of the Access Manager and
Access Manager Terminal
The inputs and outputs are assigned as follows:
Input 1 =
Door contact (opener)
Input 2 =
External door opening contact (release button/closer)
Output =
Potential-free relay-changeover contact (e. g. for triggering
the actuator)
The upper LED is permanently red in standby mode. The upper red LED goes
out if an authorised locking medium is presented. The four LEDs light up
green (only one lower LED for ELS) and you will hear an audible signal as
appropriate.
If data are read from the locking medium or written to the locking medium, the
upper red LED goes out and the four LEDs (only the one lower LED for ELS)
flash purple during the reading/writing process. Once the reading/writing
process is complete, the four LEDs (only the one lower LED for ELS) light up
green alternately for the duration of the contact hold time. After this, the upper
LED lights up red again permanently.
The output is actuated for the set contact hold time. This is set to five seconds
in its delivery state. The four LEDs (only one lower LED for ELS) light up green
alternately during this period.
The output and the green lights are switched off once the contact hold time
has elapsed. After this, the upper LED lights up red again permanently.
If the external door opening contact is activated, the signalling and activation
of the output occurs to the same extent as if an authorised locking medium
was displayed.
The locking medium can be read on both units (HiSec). The clearance for an
authorised locking medium is signalled on both units simultaneously. An
unauthorised locking medium is only signalled on the reader where it was
presented.