Dolphin pro HD+ 24V100A Technical Manual Download Page 6

NOT-DOLPROHD-00 

NOT-DOLPROHD-00

CONNECTIONS

Identification

Functions

L

AC mains power phase, max. 
10mm² (wire colour code: brown or 
black)

N

AC mains power neutral, max. 
10mm² (wire colour code: blue, 
white or red)
AC mains power earth, max. 
10mm² (wire colour code: green/
yellow or green)

-DC

Battery negative (common), pin M8 
(wire colour code: black)

+DC1

Main battery positive, pin M8 (wire 
colour code: red)

+DC2

Auxiliary 2 battery positive, pin M8 
(wire colour code: red)

+DC3

Auxiliary 3 battery positive, pin M8 
(wire colour code: red)

CHARGE 
SELECT

Curve and battery charge mode 
selector, 10 positions (0 to 9)

BATTERY FUSES

Battery protection fuses (on the 
–DC supply)

EXT TOUCH

CAN bus for TOUCH screen con-
nection

EXT COM1
& COM2

CAN bus for network operation

ID SELECT

Configuration charger ID (network 
operation)

TEMP SENSOR

Battery temperature sensor 
(2 wires no polarity, no direction)

RELAY

Alarm dry contact

CONNECTIONS

AC CABLES AND CIRCUIT BREAKER

AC wiring

Check that cables are properly connected and 

that the connections are tight.

For the mains power supply, it is preferable to use 

an  industrial  cable,  type  HO7RNF.  Observe  the 

recommendations below.

AC circuit breaker

The  AC  mains  power  line  must  have  an  on/

off  switch  with  integral  differential  protection, 

to  protect  persons,  notably  in  cases  of  electric 

shock.

Circuit  breaker  sensitivity  must  be  30mA.  The 

circuit breaker current rating must correspond to 

the  charger  consumption.  For  this,  observe  the 

recommendations below.

Nota  :  The  charger  has  an  internal  protection  fuse 
on  access  L,  which  notably  protects  against  a 
general  fault  on  the  electronics  board.  As  the  fault 
concerned is permanent, this fuse is not accessible for 
maintenance.

Charger rating

230VAC 50Hz
Length < 5m (16ft)

115VAC 60Hz
Length < 5m (16ft)

24V 40A

2.5mm² / AWG13

4mm² / AWG11

24V 60A

2.5mm² / AWG13 

4mm² / AWG11

24V 100A

4mm² / AWG11

6mm² / AWG9

Charger rating

Mains power 230V 
50Hz

Mains power 115V 
60Hz

24V 40A

8A – 30mA

16A – 30mA

24V 60A

10A – 30mA

20A – 20mA

24V 100A

20A – 30mA

-

Summary of Contents for pro HD+ 24V100A

Page 1: ...TECHNICAL MANUAL EN 24V40A REYA Code 399 165 24V60A REYA Code 399 175 24V100A REYA Code 399 185 Battery charger...

Page 2: ...cm all around the case to allow proper convection 4This device must not be exposed to running water water spray or dust of any nature 4It is recommended that the charger be mounted vertically with the...

Page 3: ...functions 4Also the charger emits conducted and radiated interference at levels compliant with applicable regulations Ensure that other equipment used close to the charger is electro magnetically comp...

Page 4: ...ger 4Installation manual 4Mains power cable grommet with its mounting nut to be installed on the case before connecting the cables 4Battery temperature sensor Preliminary checks Check the charger iden...

Page 5: ...remove it Before connecting the cables the mains power cable grommet must be installed and properly mounted on the case in its specific hole hole on left when viewed from the front of the charger The...

Page 6: ...ct CONNECTIONS AC CABLES AND CIRCUIT BREAKER AC wiring Check that cables are properly connected and that the connections are tight For the mains power supply it is preferable to use an industrial cabl...

Page 7: ...they should be replaced by fuses with identical characteristics and performance Risk of permanent damage to the charger It is necessary and strongly recommended that a connections protection fuse be...

Page 8: ...sent a health hazard Curve No 9 is compatible with a LiFeSo4 battery on condition that the battery has a BMS Battery Management System protection function You should refer to the battery manufacturer...

Page 9: ...Delphi type V BOOST V FLOAT 30 8V 27 6V Charge curve 5 Winter storage open lead acid V BOOST V FLOAT 28 8V 26 4V Charge curve 7 GEL AGM V BOOST V FLOAT 28 8V 27 6V Charge curve 8 Power supply V FLOAT...

Page 10: ...in cases where the ambient temperature in the battery room is high The sensor is screwed onto the main battery positive terminal generally ancillary The 2 wires are connected to the TEMP SENSOR conne...

Page 11: ...NOT DOLPROHD 00 NOT DOLPROHD 00 OPERATION OPERATION EN...

Page 12: ...acid V BOOST 28 8V V FLOAT 26 4V Winter storage sealed lead acid V BOOST 28 4V V FLOAT 27 2V 24V 40A 24V 60A 24V 100A Gel AGM V BOOST 28 8V V FLOAT 27 6V Power supply V FLOAT 27 2V LiFeSo4 integral B...

Page 13: ...C 60068 2 64 vibration test IEC publication No 60529 IP SAFETY EN 60335 1 DNV Classification Control room Accommodation Dimensions 24V 40A 24V 60A 24V 100A Check that the mounting screws used are comp...

Page 14: ...ed causing malfunctions or permanent damage to the charger 4Operating the charger on an unsuitable power supply generally a mains power voltage that is too high 4Accidental mains power overvoltage or...

Page 15: ...For all information contact REYA SAS 2599 route de la F nerie 06580 P gomas France Tel 33 0 4 93 90 47 00 Fax 33 0 4 93 47 42 57 e mail reya reya com www reya com...