22 User manual roll towel dispenser series DP 3107 / DP 3108 / DP 3109 / DP 3110
Make 5.3 Basic settings
When the door is open, the motor of the electrical
system is disconnected, so that no accidental
running of the dispenser is possible.
The following settings are possible:
●
Paper length can be specified between 20cm to
120cm. The paper length is subject in battery-
powered devices depending on the battery
condition slight fluctuations.
●
‘Dead time’ from 1 second to 6 seconds can be
specified between the dispensing of sheets; this
trigger lock time starts right after the paper
dispensing process.
●
During this ‘dead time’ period, no paper request is
possible. The set time is shown by the LED. The
LED lights after the dispensing of the paper for the
set ‘dead time’.
Factory settings on the roller towel dispenser :
●
Paper speed: approx 45cm
●
Dead time: 1 second
●
The sensor LED lights up green each time that a
hand approaches the sensor.
●
The battery LED flashes red when the batteries are
need replacing – always replace all of the batteries
at the same time.
Paper length Dead time
20cm 120cm 1 s 5 s
Battery
LED
Sensor LED
Sensor LED
Manual run