10
DOLMAR GmbH
1
3
2
4
04 Ignition system
04-04 Removing the ignition armature
Unscrew starting device.
Remove the two screws (1) of the ignition
armature. Clip off ignition and short circuit
cable.
04-04 Mounting the ignition armature
Connect ignition and short circuit cable.
Position setting gauge 944.500.890 (arrow)
between ignition device and magnet on the
flywheel. Press ignition device firmly whilst at
the same time tightening the screws evenly.
04-05 Mounting the flywheel
Before mounting the flywheel, the cone seat
and the crankshaft (4) must be cleaned.
Note. The flywheel is tightened with a torque
of 30Nm (see page 22).
04-04 Checking the ignition armature
In the event of a fault, first check the ignition
earth connection. To do this, loosen and then
tighten the screws (1) a few times. then check
ignition once again.
04-05 Removing the flywheel
Block the transmission using the piston stop
wedge. Unscrew bolt (2) and remove washer
(3). Remove flywheel with pulling device
957.427.010.
Warning: to avoid damage to the crankshaft
always use the protective cap including with
the pulling device.
Summary of Contents for PC-7312 HappyStart