7 ENGLISH
ENGLISH (Original instructions)
SPECIFICATIONS
Model
ES-154
ES-154
TLC
ES-164
ES-164
TLC
ES-174
ES-174
TLC
ES-184
ES-184
TLC
ES-2131 ES-2131
TLC
ES-2136 ES-2136
TLC
ES-2141 ES-2141
TLC
ES-2146 ES-2146
TLC
Max. chain speed
14.5 m/s (870 m/min)
Standard guide bar
Bar length
300 mm
350 mm
400 mm
450 mm
Cutting length
260 mm
320 mm
355 mm
415 mm
Guide bar type
Sprocket nose bar
Standard saw chain
Type
492 (91PX)
Pitch
3/8"
No. of drive links
46
52
56
62
Recommended guide bar length
300 - 450 mm
Overall length (without guide bar)
505 mm
Net weight
5.4 kg
5.5 kg
5.5 kg
5.6 kg
5.7 kg
Extension cable (optional)
DIN 57282/HO 7RN -F L=30 m max.,3x1.5 mm
2
• Due to our continuing program of research and development, the specifications herein are subject to change with
-
out notice.
• Specifications may differ from country to country.
• Weight according to EPTA-Procedure 01/2003
Symbol
The following show the symbols used for the equip-
ment. Be sure that you understand their meaning before
use.
Read instruction manual and follow the
warnings and safety instructions.
Wear eye protection.
Wear ear protection.
DOUBLE INSULATION
Caution: particular care and attention
required!
Caution: withdraw the mains plug immedi-
ately if the cable is damaged!
Caution: kickback!
Protect against rain and damp!
Wear a helmet, goggles and ear protection!
Wear safety gloves!
Withdraw the mains plug!
First aid
Maximum permissible length of cut
Direction of chain travel
Chain oil
Chain brake released
Chain brake applied
Prohibited!
Only for EU countries
Do not dispose of electric equipment
together with household waste material!
In observance of the European Directive,
on Waste Electric and Electronic Equipment
and its implementation in accordance with
national law, electric equipment that have
reached the end of their life must be col-
lected separately and returned to an envi-
ronmentally compatible recycling facility.
Intended use
The tool is intended for cutting lumbers and logs.
Power supply
The tool should be connected only to a power supply of
the same voltage as indicated on the nameplate, and
can only be operated on single-phase AC supply. They
are double-insulated and can, therefore, also be used
from sockets without earth wire.
Summary of Contents for ES-154
Page 2: ...1 2 1 1 1 2 1 3 1 2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 2 ...
Page 4: ...1 2 3 5 4 1 2 3 1 3 2 1 1 A B A B Fig 17 Fig 18 Fig 19 Fig 20 Fig 21 Fig 22 Fig 23 Fig 24 4 ...
Page 6: ...30 1 2 1 1 1 2 Fig 33 Fig 34 Fig 35 Fig 36 Fig 37 Fig 38 Fig 39 Fig 40 6 ...
Page 146: ...146 ...
Page 147: ...147 ...