Evisceration/Disembowelment

: A negative

  pressure applied directly to the intestines through  

 

an unprotected suction outlet sump or suction outlet  

  cover which is damaged, broken, cracked, 

 

  missing, or unsecured can result in evisceration/ 

 disembowelment.

  Mechanical  Entrapment

: There is potential for  

  jewelry, swimsuits, hair decorations, fingers, toes,  

  or knuckles to be caught in an opening of a suction  

  outlet cover resulting in mechanical entrapment.

WARNING

 

Reduce Risk of Entrapment Hazards.

14. When outlets are small enough to be blocked by a  

  person, a minimum of two functioning suction  

  outlets per pump must be installed. Suction outlets  

  in the same plane (floor or wall), must be installed  

 

a minimum of 3 feet [0.91 meter] apart, as measured  

  from near point to near point.

  • Dual  suction  fittings  shall  be  placed  in  such  

 

  locations and distances to avoid ‘dual blockage’ by  

    a user.

  • Dual suction fittings shall not be located on seating  

    areas or on the backrest for such seating areas.

  • The maximum system flow rate shall not exceed  

    the values shown in the ‘Pipe Sizing Chart’ found  

    at this manual.

  • Never  use  pool  or  spa  if  any  suction  outlet  

 

  component is damaged, broken, cracked, missing,  

    or not securely attached.

  • Replace  damaged,  broken,  cracked,  missing,  

 

  or not securely attached suction outlet components  

   immediately.

  • Installation of a vacuum release or vent system,  

    recommended, relieves entrapping suction.

▲WARNING  Hazardous Pressure. 

15. Pool and spa water circulation systems operate  

  under hazardous pressure during start-up, normal  

  operation, and after pump shut-off. Stand clear  

  of circulation system equipment during pump start- 

 

up. Failure to follow safety and operation instructions  

  could result in violent separation of the pump  

  housing and cover due to pressure in the system,  

  which could cause property damage, severe 

 

  personal injury, or death. Before servicing pool and  

  spa water circulation system, all system and pump  

  controls  must  be  in  off  position  and  filter  manual  

  air relief valve must be in open position. Before  

  starting system pump, all system valves must be  

  set in a position to allow system water to return  

  back to the pool. Do not change filter control valve  

  position while system pump is running. Before  

  starting system pump, fully open filter manual air  

  relief  valve.  Do  not  close  filter  manual  air  relief  

  valve until a steady stream of water (not air or air  

  and water) is discharged. All suction and discharge  

 valves 

MUST

 be 

OPEN

 when starting the circulation  

  system. Failure to do so could result in severe  

  personal injury and/or property damage.

▲WARNING  Separation Hazard. 

16. Failure to follow safety and operation instructions  

  could result in violent separation of pump 

 

  components. Strainer cover must be properly 

 

  secured to pump housing with strainer cover 

 

  lock ring. Before servicing pool and spa circulation  

  system, all system and pump controls must be in  

  off position and filter manual air relief valve must  

  be in open position. Do not operate pool and  

  spa circulation system if a system component is  

  not assembled properly, damaged, or missing. Do  

  not operate pool and spa circulation system unless  

  filter air relief valve body is in locked position in filter  

 

upper body. All suction and discharge valves 

MUST

  

 be 

OPEN

 when starting the circulation system.  

  Failure to do so could result in severe personal  

  injury and/or property damage.

17. Never operate or test the circulation system at  

  more than 40 psi.

▲WARNING  Fire and burn hazard. 

18. Motors operate at high temperatures and if they are  

  not properly isolated from any flammable structures  

  or  foreign  debris,  they  can  cause  fires,  which  

  may cause severe personal injury or death. It is  

  also necessary to allow the motor to cool for at  

  least 20 minutes prior to maintenance to minimize  

  the risk for burns.

19. Motor must be grounded in accordance with local  

  and national electrical codes. 

20. To prevent electrical shock or injury, do not run  

  pump dry.

21. To reduce the risk of electric shock, install at least  

  10 feet from the inside walls of the pool. Do not use  

  an extension cord.  

CHAPTER 2

: INSTALLATION INSTRUCTIONS

▲WARNING

 

This product should be installed and  

  serviced only by a qualified professional.

1. 

Pump Mounting

: Install pump on a firm, level base  

  or pad to meet all local and national codes. Fasten  

  pump to base or pad with screws or bolts to further  

  reduce vibration and stress on pipe or hose joints.  

  The base MUST be solid, level, rigid, and vibration free.

  Pump Mount Must

:

  • Allow  pump  inlet  height  to  be  as  close  to  water  

    level as possible.

  • Allow use of short, direct suction pipe (to reduce  

    friction losses).

  • Allow  for  gate  valves  in  suction  and  discharge  

   piping.

  • Be protected from excess moisture and flooding.

6950 51st Street Kenosha WI 53144 | Orders and Customer Care: 1-800-574-7665 | Fax: 1-800-323-5932 | Doheny.com 

Summary of Contents for 2601

Page 1: ...y SAVE THIS INSTRUCTION MANUAL Use of appointed replacement parts voids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY INSTALLATION OPERATION PARTS Above Ground Pump Item s 2601 6578 6579...

Page 2: ...icable local and national codes and regulations Before working on pump or motor disconnect motor wiring 6 Toreducetheriskofelectricshock replacedamaged cord immediately Do NOT bury cord Locate cord to prevent abuse from lawn mowers hedge trimmers and other equipment 7 Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a professional...

Page 3: ...ual air relief valve until a steady stream of water not air or air and water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separation Hazard 16 Failure to follow safety and operation instructions could result in violent separation of pump components Strainer cov...

Page 4: ...e to ground and bond pump motor can cause serious or fatal electrical shock hazard 2 Do NOT ground to a gas supply line 3 To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections 4 Ground Fault Circuit Interrupter GFCI tripping indicates electrical problem If GFCI trips and won t reset consult electrician to inspect and repair electrical system ...

Page 5: ...s Immediately inspect all parts to verify they are intact and functioning properly Fill strainer housing with water to suction pipe level NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal WARNING If pump is being pressure tested 40 psi MAXIMUM be sure pressure has been released using the filter manual air relief valve before removing strainer ...

Page 6: ...ONS Modifications done to the pumps will void the warranty When servicing electrical equipment basic safety precautions should always be observed including the following Failure to follow instructions may result in injury A To reduce risk of injury do not permit children to use this product B Disconnect all electrical power service to pump before beginning shaft seal replacement C Only qualified p...

Page 7: ...nsure that the motor is rotating at full RPM s iii Open housing cover and check for clogging or obstruction in suction Check impeller for debris iv Remove and replace shaft seal only if it is leaking E Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct piping size 3 Plugged or rest...

Page 8: ...1 inches 21 75 inches 8 inches Floor to Suction Port 6 5 inches Floor to Suction Port 8 inches Floor to Suction Port 9 75 inches Floor to Discharge Hose 12 inches Floor to Discharge Hose 7 75 inches Floor to Discharge Hose 6950 51st Street Kenosha WI 53144 Orders and Customer Care 1 800 574 7665 Fax 1 800 323 5932 Doheny com ...

Page 9: ...ffuser 1 8a 116578 Impeller for 1 HP Pump 2716 1 8b 126578 Impeller for 1 5 HP Pump 6589 1 9 136578 O Ring 1 10 146578 Pump Cover 1 11 156578 Gasket M10 6 12 166578 Screw 3 8 16 1 1 2 UNC 6 13 176578 Seal Assembly 1 14 186578 Supporting Foot 1 15 196578 Mounting Foot 1 16 206578 Screw M6x20 2 17 216578 Gasket M6 2 18 226578 Nut M6 2 19 236578 Nut 3 8 16 6 20 56578 Drain Gasket 1 21 66578 Drain Plu...

Page 10: ... 1 5 286578 Strainer Housing 1 6 296578 Pump Cover 1 7a 306578 Impeller for 3 4 HP Pump 2601 1 7b 316578 Impeller for 1 HP Pump 6578 1 7c 326578 Impeller for 1 5 HP Pump 6579 1 8 336578 Seal Assembly 1 9 346578 Pump Housing 1 10 356578 O Ring 1 11 366578 Screw ST5 5x25 8 12 376578 O Ring 1 13 56578 Drain Gasket 1 14 66578 Drain Plug 1 15 386578 Motor Mounting Plate 1 16a 396578 3 4 HP Motor for 26...

Page 11: ... 65431032080 O Ring 1 6 647254203080 Diffuser 1 7b 647274371000 Impeller for 1 HP Pump 4657 1 7c 647254271000 Impeller for 1 5 HP Pump 5014 1 8 65431075080 O Ring 1 9 647254202080 Pump Cover 1 10 65244005000 Gasket M8 8 11 65221009000 Screw M8X40 8 12 65028003000 Seal Assembly 1 13 65231004106 Nut M8 8 14 65432002080 Gasket 1 15 648860105080 Drain Plug 1 16 647254205080 Foot Insert 1 17 6472542040...

Page 12: ...as a result of freezing negligence improper installation use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No r...