Doheny's 2601 Installation, Operation & Parts Download Page 2

6950 51st Street Kenosha WI 53144 | Orders and Customer Care: 1-800-574-7665 | Fax: 1-800-323-5932 | Doheny.com 

Symbol means:

DANGER

 

  Indicates that if failure to avoid potential hazard,   

 

will

 cause severe personal injury or death or  

  property damage.

WARNING

 

  Indicates that failure to avoid potential hazard,  

 

could

 result in severe personal injury or death or  

  property damage.

CAUTION

 

  Indicates that failure to avoid potential hazard, 

will  

  or could

 cause moderate personal injury or 

 

  property damage.

CHAPTER 1

:

IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
▲WARNING  Pay Attention to Children.

1.  To reduce risk of injury, do not permit children to use  

  or climb on this product. Closely supervise children  

  at  all  times.  Components  such  as  the  filtration  

  system, pumps, and heaters must be positioned to  

  prevent children from using them as a means of  

  access to the pool.

2.  This pump is intended for use on permanently  

 

installed swimming pools and may also be used with  

  hot tubs and spas if so marked. Do 

NOT

 use with  

  storable pools. A permanently installed pool is  

 

constructed in or on the ground or in a building such  

 

that it cannot be readily disassembled for storage. A  

  storable pool is constructed so that it is capable  

  of being readily disassembled for storage and  

  reassembled to its original integrity.

3.  Though this product is designed for outdoor use, it is  

 

strongly advised to protect the electrical components  

 

from the weather. Select a well-drained area, one that  

  will not flood when it rains. It requires free circulation  

  of air for cooling. Do not install in a damp or non- 

  ventilated location.

4.  Pool  and  spa  components  have  an  finite  life. All  

  components  should  be  inspected  frequently  and  

  replaced at least every five years, or if found to be  

 

damaged, broken, cracked, missing, or not securely  

 attached.

▲WARNING  Risk of Electric Shock. 

  Applies to Inground Pumps

5.  Hazardous voltage. Can shock, burn, or cause  

  death. To reduce the risk of electric shock, do NOT  

  use an extension cord to connect unit to electric  

  supply. Provide a properly located outlet. It is  

  required that licensed electricians do all electrical  

 

wiring. All electrical wiring MUST be in conformance  

  with applicable local and national codes and 

 

  regulations. Before working on pump or motor,  

  disconnect motor wiring.

6.  To reduce the risk of electric shock, replace damaged  

 

cord immediately. Do NOT bury cord. Locate cord to  

  prevent abuse from lawn mowers, hedge trimmers  

  and other equipment.

7.  Risk of Electric Shock. Connect only to a branch  

  circuit protected by a ground-fault circuit-interrupter  

  (GFCI). Contact a professional electrician if you  

  cannot verify that the receptacles are protected by  

  a GFCI.

8.  Failure to bond pump to pool structure will increase  

  risk for electrocution and could result in injury  

  or death. To reduce the risk of electric shock, see  

  installation instructions and consult a professional  

  electrician on how to bond pump. Also, contact a  

 

licensed electrician for information on local electrical  

  codes for bonding requirements.

9.  Use a solid copper conductor, size 8 or larger.  

  Run a continuous wire from external bonding lug to  

  reinforcing rod or mesh. Connect a No. 8 AWG  

 

(8.4 mm

2

) solid copper bonding wire to the pressure  

  wire connector provided on the motor housing and  

  to all metal parts of swimming pool, spa, or hot tub,  

  and to all electrical equipment, metal piping (except  

 

gas piping), and conduit within 5 feet (1.5m) of inside  

  walls of swimming pool, spa or hot tub. 

 IMPORTANT

: Reference NEC codes for all wiring  

  standards including, but not limited to, grounding,  

  bonding and other general wiring procedures. 

 NOTE

: The National Electrical Code (NEC) permits  

  use of a cord with a maximum 3 feet (1m) length. If  

  your pump is equipped with a cord complying with  

  the NEC, the preceding four hazards apply.

10. Do not install within an outer enclosure or beneath  

  the skirt of a hot tub or spa.

11. 

SAVE THESE INSTRUCTIONS

.

12. These pumps are not pool side pumps.

▲WARNING  Suction Entrapment Hazard.

13. Suction in suction outlets and/or suction outlet  

  covers, which are damaged, broken, cracked, 

 

  missing, or unsecured, cause severe injury and/or  

  death due to the following entrapment hazards:

  Hair Entrapment

: Hair can become entangled in  

  suction outlet cover.

  Limb Entrapment

: A limb inserted into an opening  

  of a suction outlet sump or suction outlet cover that  

  is damaged, broken, cracked, missing, or not 

 

  securely attached can result in a mechanical bind  

  or swelling of the limb.

  Body Suction Entrapment

: A pressure applied to  

  a large portion of the body or limbs can result in an  

 entrapment.

 

Summary of Contents for 2601

Page 1: ...y SAVE THIS INSTRUCTION MANUAL Use of appointed replacement parts voids warranty ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS PUMP THAT MUST BE PROVIDED TO THE END USER OF THIS PRODUCT FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY INSTALLATION OPERATION PARTS Above Ground Pump Item s 2601 6578 6579...

Page 2: ...icable local and national codes and regulations Before working on pump or motor disconnect motor wiring 6 Toreducetheriskofelectricshock replacedamaged cord immediately Do NOT bury cord Locate cord to prevent abuse from lawn mowers hedge trimmers and other equipment 7 Risk of Electric Shock Connect only to a branch circuit protected by a ground fault circuit interrupter GFCI Contact a professional...

Page 3: ...ual air relief valve until a steady stream of water not air or air and water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separation Hazard 16 Failure to follow safety and operation instructions could result in violent separation of pump components Strainer cov...

Page 4: ...e to ground and bond pump motor can cause serious or fatal electrical shock hazard 2 Do NOT ground to a gas supply line 3 To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections 4 Ground Fault Circuit Interrupter GFCI tripping indicates electrical problem If GFCI trips and won t reset consult electrician to inspect and repair electrical system ...

Page 5: ...s Immediately inspect all parts to verify they are intact and functioning properly Fill strainer housing with water to suction pipe level NEVER OPERATE THE PUMP WITHOUT WATER Water acts as a coolant and lubricant for the mechanical shaft seal WARNING If pump is being pressure tested 40 psi MAXIMUM be sure pressure has been released using the filter manual air relief valve before removing strainer ...

Page 6: ...ONS Modifications done to the pumps will void the warranty When servicing electrical equipment basic safety precautions should always be observed including the following Failure to follow instructions may result in injury A To reduce risk of injury do not permit children to use this product B Disconnect all electrical power service to pump before beginning shaft seal replacement C Only qualified p...

Page 7: ...nsure that the motor is rotating at full RPM s iii Open housing cover and check for clogging or obstruction in suction Check impeller for debris iv Remove and replace shaft seal only if it is leaking E Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct piping size 3 Plugged or rest...

Page 8: ...1 inches 21 75 inches 8 inches Floor to Suction Port 6 5 inches Floor to Suction Port 8 inches Floor to Suction Port 9 75 inches Floor to Discharge Hose 12 inches Floor to Discharge Hose 7 75 inches Floor to Discharge Hose 6950 51st Street Kenosha WI 53144 Orders and Customer Care 1 800 574 7665 Fax 1 800 323 5932 Doheny com ...

Page 9: ...ffuser 1 8a 116578 Impeller for 1 HP Pump 2716 1 8b 126578 Impeller for 1 5 HP Pump 6589 1 9 136578 O Ring 1 10 146578 Pump Cover 1 11 156578 Gasket M10 6 12 166578 Screw 3 8 16 1 1 2 UNC 6 13 176578 Seal Assembly 1 14 186578 Supporting Foot 1 15 196578 Mounting Foot 1 16 206578 Screw M6x20 2 17 216578 Gasket M6 2 18 226578 Nut M6 2 19 236578 Nut 3 8 16 6 20 56578 Drain Gasket 1 21 66578 Drain Plu...

Page 10: ... 1 5 286578 Strainer Housing 1 6 296578 Pump Cover 1 7a 306578 Impeller for 3 4 HP Pump 2601 1 7b 316578 Impeller for 1 HP Pump 6578 1 7c 326578 Impeller for 1 5 HP Pump 6579 1 8 336578 Seal Assembly 1 9 346578 Pump Housing 1 10 356578 O Ring 1 11 366578 Screw ST5 5x25 8 12 376578 O Ring 1 13 56578 Drain Gasket 1 14 66578 Drain Plug 1 15 386578 Motor Mounting Plate 1 16a 396578 3 4 HP Motor for 26...

Page 11: ... 65431032080 O Ring 1 6 647254203080 Diffuser 1 7b 647274371000 Impeller for 1 HP Pump 4657 1 7c 647254271000 Impeller for 1 5 HP Pump 5014 1 8 65431075080 O Ring 1 9 647254202080 Pump Cover 1 10 65244005000 Gasket M8 8 11 65221009000 Screw M8X40 8 12 65028003000 Seal Assembly 1 13 65231004106 Nut M8 8 14 65432002080 Gasket 1 15 648860105080 Drain Plug 1 16 647254205080 Foot Insert 1 17 6472542040...

Page 12: ...as a result of freezing negligence improper installation use or care shall be replaced at our option without charge within 90 days of the receipt of defective product barring unforeseen delays After 90 days to obtain warranty replacements defective components should be returned transportation paid to the place of purchase For further Doheny s service contact Doheny s cus tomer care department No r...

Reviews: