Preparing for a Docking Drawer Installation–

To prepare for a successful Docking Drawer installation please ensure that the cable management arms 
are free and unobstructed by confirming following the specifications:

•­ The­distance­from­the­back­of­the­drawer­to­the­

wall­where­the­power­cord­bracket­mounts­must­

be­at­least­3"­as­shown.

•­ The­inside­depth­of­the­drawer­must­be­at­

least­2­

3

/

4

"

•­ The­drawer­glides­must­be­positioned­in­such­as­

way­that­the­drawer­extends­no­more­than­18"­

for­0290-00030(W)­and­21"­for­0290-00031(W).

•­ The­cutout­for­the­receptacle­box­should­be­

1

/

32

"­wide­X­2­

15

/

16

"­high.­Enlarging­the­cutout­

by­

1

/

16

"­in­each­dimension­is­acceptable­for­ease­

of­mounting.­The­installer­must­provide­(4)­mounting­

screws­for­the­receptacle­box­and­(2)­for­the­power­

cord­bracket.

•­ The­receptacle­box­accepts­drawer­wall­thicknesses­ 

of­either­

1

/

2

"­or­

5

/

8

".

Summary of Contents for DD 21 Slim

Page 1: ...nformation The Docking Drawer has been listed by ETL and complies with UL 962a and CSA C22 2 when installed in accordance with these instructions Do not install this product in a manner contrary to these instructions The Docking Drawer is designed for charging personal electronics and other low power devices It is limited to a maximum of 3A 120 VAC Current installation diagrams mounting diagrams a...

Page 2: ...wer to the wall where the power cord bracket mounts must be at least 3 as shown The inside depth of the drawer must be at least 2 3 4 The drawer glides must be positioned in such as way that the drawer extends no more than 18 for 0290 00030 W and 21 for 0290 00031 W The cutout for the receptacle box should be 6 1 32 wide X 2 15 16 high Enlarging the cutout by 1 16 in each dimension is acceptable f...

Page 3: ... receptacle box cut out in the back of the drawer 4 Insert the right rear mounting screw not supplied 5 Mount the receptacle box 6 Test movement Align cable management arms so they are centered between the drawer box and the back of the cabinet if necessary 7 Plug in Docking Drawer outlet into an existing electrical outlet 3 Extend the Docking Drawer outlet and insert the left rear mounting screw ...

Page 4: ...he wires from the cable management arms into the receptacle box and reattach the bracket using the screwdriver and 2 10 screws 7 Secure the receptacle box to the back of the drawer using the installer supplied hardware 8 Reconnect the black wire from the circuit breaker to the black wire from the cable management arm using the blue wire nut 9 DO NOT FORGET TO REATTACH THE GROUND WIRE INSIDE THE RE...

Page 5: ...rdance with those instructions Specifications Docking Drawer Technical Specifications AC Power 125V tamper resistant NEMA 5 15R duplex receptacle DC USB Power 5 2V 12 5W duplex USB charging receptacle with integrated on off safety switch Max rated current 125 VAC 3A Circuit is protected by 5A pop out breaker accessible from the user side Designed for charging personal electronic devices only Opera...

Reviews: