background image

3

Installing the Docking Drawer Slim USB Outlet–

1.

   With the drawer closed and the receptacle box in 

position, mark the location of the rear mounting 

bracket so that the arms are centered.

2.

   Insert Docking Drawer outlet through the  

receptacle box cut out in the back of the drawer.

4.

   Install the right rear mounting screw  

(not supplied).

5.

  Mount the receptacle box.

6.

   Test movement. Align cable management arms 

so they are centered between the drawer box 

and the back of the cabinet if necessary.

7.   

Plug in Docking Drawer outlet into an existing 

electrical outlet.

3.

   Extend the Docking Drawer outlet and install 

the left rear mounting screw (not supplied).

Summary of Contents for 0290-00046(W)

Page 1: ...cal electrical codes General Information The Docking Drawer Slim USB Series has been listed by ETL and complies with UL 962a and CSA 22 2 when installed in accordance with these instructions Do not install this product in a manner contrary to these instructions The Docking Drawer Slim USB Series is designed for charging personal electronics and other low power devices It is limited to a maximum of...

Page 2: ...nce from the back of the drawer to the wall where the power cord bracket mounts must be at least 3 as shown The minimum interior drawer box height must be at least 2 3 4 The drawer slides must be positioned in such as way that the drawer extends no more than 21 for 0290 00046 W 18 for 0290 00045 W and 15 for 0290 00048 W The cutout for the receptacle box should be 6 1 32 wide X 2 15 64 high Enlarg...

Page 3: ...ugh the receptacle box cut out in the back of the drawer 4 Install the right rear mounting screw not supplied 5 Mount the receptacle box 6 Test movement Align cable management arms so they are centered between the drawer box and the back of the cabinet if necessary 7 Plug in Docking Drawer outlet into an existing electrical outlet 3 Extend the Docking Drawer outlet and install the left rear mounti...

Page 4: ... the wires from the cable management arms into the receptacle box and reattach the bracket using the screwdriver and 2 10 screws 7 Secure the receptacle box to the back of the drawer using the installer supplied hardware 8 Reconnect the black wire from the circuit breaker to the black wire from the cable management arm using the blue wire nut 9 DO NOT FORGET TO REATTACH THE GROUND WIRE INSIDE THE ...

Page 5: ...wires in accordance with those instructions Specifications Docking Drawer Slim USB Technical Specifications DC USB Power 5 2V 12 5W duplex USB charging receptacle with integrated on off safety switch Max rated current 125 VAC 3A Circuit is protected by 5A pop out breaker accessible from the user side Designed for charging personal electronic devices only Operation Instructions specific to the USB ...

Page 6: ...00011 W 0290 00049 W 0290 00033 W 0290 00032 W 0290 00050 W Cabinet Specifications Maximum drawer extension 21 18 15 21 18 15 20 17 14 20 17 14 Minimum width behind drawer box 17 1 2 16 14 1 2 17 1 2 16 14 1 2 13 1 2 12 10 1 2 13 1 2 12 10 1 2 Minimum space behind drawer box 3 3 3 3 3 3 4 4 4 5 5 5 Minimum interior drawer box height 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 4 4 4 4 4 4 Charging Receptac...