In Case of Difficulty

If your recorder does not work properly, try the following suggestions before seeking 
repair assistance.

Symptom

Solution

Display does not turn on

Check if batteries are inserted with correct
polarity.
The batteries are weak. Replace new batteries.
Check if the buttons are locked with the HOLD
switch.

The unit cannot record message 

Check if memory is full, 

F

 and 

will displayed. Try erasing some messages or
download to PC to make room for new one.
99 messages have been recorded in the selected
file. Select another file or erase some of the
message.

memory full

No sound comes from the speaker

The earphone is plugged in.
The volume is turned down completely.

Recording level is low

Try a closer distance between microphone and
the sound source during recording.
Microphone sensitivity is set to '

'. Set it to

' '.

Lo

Hi

Noise or 'SCRATCHY' sound
during playback

An object, such as your finger, etc. accidentally 
rubbed or scratched the unit during recording.
Noise was recorded.

The unit does not operate
correctly

Take out the batteries and reinsert it again.
Press the reset switch 

(inside the small hole in

battery compartment)

 by using a small ball-point

pen etc.

(The unit will reset to the factory default settings, 
but the recorded messages will remain)

If you continue to have problems, contact your local dealer where you purchase the unit.

- 24 -

- 23 -

Additional Information

Declaration

The product function maybe reset when it is subjected to electrostatic

discharge disturbance.  Just follow the instruction described in this

manual to set the function again for normal operation.

This device complies with part 15 of the FCC Rules. Operation is 

subject to the following two conditions: (1) This device may not cause 

harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class 
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates, uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instruction, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not 
occur in a particular installation. If this equipment does cause harmful interference to 
radio or television reception, which can be determined by turning the equipment off 
and on, the user is encouraged to try to correct the interference by one or more of the 
following measures:

-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which 
    the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.

Summary of Contents for VoiceStick 440

Page 1: ...chrichtentechnik Entwicklungs und Vertriebs GmbH Voltastra e 4 D 63128 Dietzenbach Tel 49 0 6074 3714 0 Fax 49 0 6074 3714 37 Internet http www dnt de Email dnt dnt de Serien Nr Serial no Kaufdatum Da...

Page 2: ...X V oiceActivatedRecording Menu Settings Recording with line in and telephone adaptor MODE Recording Mode Setting SOUR C Input Source Setting V OX V oiceActivated Recording Setting SE NSE Microphone S...

Page 3: ...files transfer between folders Adjustable speaker volume Battery Low indication Memory capacity indication Audio jack for external headset microphone Compact size ready to use from your pocket PC Lin...

Page 4: ...ries as soon as possible Battery life See Page 25 Replacing the Batteries Do not use manganese batteries Do not mix old and new batteries different types of batteries or rechargeable batteries of diff...

Page 5: ...by mode after powered on or 60 seconds after recording message playback You can enter standby mode manually by pressing the button after recording message playback Note 7 Basic Operations Recording Me...

Page 6: ...rt from Step 1 When playing back a message you have just finished recording start from Step 3 1 Press the FILE button to select or folder that you want to listen the message 2 You can scroll to the me...

Page 7: ...to skip to the message you want to move 3 Press SET and use to scroll to or option 4 Press to perform the move message operation 5 To cancel moving the message press SET before step 4 MOVE TO A B Note...

Page 8: ...end to the external device Audio or PC sound output such as earphone jack 2 Set the source to Line in See Page 15 3 Follow the same procedure as with the microphone See page 8 LINE Telephone conversa...

Page 9: ...t in a location near heat sources or in a place subject to direct sunlight excessive dusty or mechanical shock Should any solid object or liquid drop into the unit remove the batteries and have the un...

Page 10: ...dditional Information Declaration The product function maybe reset when it is subjected to electrostatic discharge disturbance Just follow the instruction described in this manual to set the function...

Page 11: ...with 99 messages per file folder Built in 23mm diameter Built in omni directional microphone 2 x AAA alkaline battery LR03 Approx 9 Hrs of continuous recording or 8 Hrs continuous playback speaker vo...

Reviews: