3. INSTALLATION
(For 2 in/2 out configuration – both PGM & PVW and 2PGM)
1.
Plug one end of a 9-conductor RS422 serial cable into the VTR1 connector on the rear of
the DMAT-MAV controller.
Plug the other end of the cable into the connector labeled P1 on the rear panel of the
MAV.
2.
In a similar manner, connector VTR2 to P2; VTR4 to R1; VTR 5 to R2.
(For 1 PGM configuration for HD MAVs)
1.
Connect VTR1 connector on the back of the DMAT to the P2 on the MAV.
2.
Connect VTR4 connector on the back of the DMAT to the R2 connector on the MAV.
(For use as a Super Slo-mo unit)
1.
Connect VTR1 connector on the back of the DMAT to the P2 on the MAV.
2.
Connect VTR4 connector on the back of the DMAT to the R1 connector on the MAV.
(For all configurations)
1.
Plug the DB9M connector from the supplied power supply into the power connector on
the rear panel of the ST400.
2.
Plug the POWER SUPPLY into a wall outlet, 90 VAC TO 240 VAC.
3.
Select REMOTE mode on the MAV's front panel.
DO NOT HOT PLUG! Always connect the power supply to the ST400
BEFORE
connecting to AC power