Addressing
The DMX-Start address is adjustable via switches 1 up to 9.
Switch 1 has the valence 2
0
(=1), switch 2 the valence 2
1
(=2) etc. until switch 9 has
the valence 2
8
(=256). In total switches showing ON correlate with the starting
address.
Switch 10 is reserved for the StandAlone-Function and must show OFF during the
DMX-Operation.
LED-Display
The integrated LED is a multifunctional-display.
During the normal DMX-Operation the LED flashes permanent. In this case the
device is working.
Furthermore the LED shows the event. In this case the LED lights in short pitches
and then turns into the off mode for a longer period. The number of flashing impulses
corresponds with the error status:
Error-
Status
Error
Description
1
No DMX
There is no DMX-Signal at the dimmer
2
Address error
Check if a valid DMX starting address is adjusted via
switches 1-9
3
DMX-Signal error
An invalid DMX-Entry signal is detected. Invert the
signal lines at pin 2 and 3 or use a twisted pair wire.
1
2
4
8
1
6
3
2
6
4
1
2
8
2
5
6