ArtNet-DMX Mux24
9
Input 17-24 Mode
The function of inputs 17-24 is set.
ArtNet Output Parameter
The ArtNet output parameters specify the values for the Art-Net™ output.
Net
/
SubNet
/
Universe
(Port) are the Art-Net™ parameter defining the aim.
The
Transmit Mode
specifies how to output data via Art-Net™.
Broadcast
sends the Art-Net™ data to all devices.
Unicast
sends the Art-Net™ data to the destinations IP device.
Under
Destination IP
the IP address is entered to which the data is to be sent via
Art-Net™ (unicast).
Send only on change
suppresses the regularly repeated output of values via ArtNet.
ArtNet Input Parameter
The ArtNet input parameter specifies the values for the Art-Net™ reception.
Net
/
SubNet
/
Universe
(Port) are the Art-Net™ parameter defining the source.
DMX Output Mode
The function of the DMX output is set.
No Output
No DMX output
Direct from Digital / Analog Inputs
DMX output of the generated values for the
digital and analog inputs
Direct from Art-Net™ Input
DMX output of the received Art-
Net™ data
Merge HTP
DMX output of the highest value of the
received Art-Net™ data and the generated
values for the digital and analog inputs
Merge REPLACE
DMX output of the received Art-Net™ data
with the replaced values of the digital and
analog inputs.
SAVE
saves the configuration.