ArtNet-DMX Mux24 

 

 
 

User manual 

 
 
 

 

 
 
 
 

 

 

Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd.

 

 

 

Summary of Contents for ArtNet-DMX Mux24

Page 1: ...ArtNet DMX Mux24 User manual Art Net Designed by and Copyright Artistic Licence Holdings Ltd...

Page 2: ...n 3 Data sheet 4 Connection 5 LED Display 6 Configuration 6 Set the IP with the IP Configurator 6 Device Configuration 8 Main 8 Digital Inputs IN1 IN16 10 Analog Digital Inputs IN17 IN24 15 Send Wake...

Page 3: ...nnels are adjustable for each input 4 configurable Timer 4 separately configurable timer allow time controlled on off switching of DMX channels Wake On LAN Send Wake On Lan WoL via button input or tim...

Page 4: ...s 16x Long Distance Digital Input 8x Analog Input or Long Distance Digital Input Modi per input Switch Button Toggle Button Dimmer Up Dimmer Down Dimmer Up Down Button On Dimmer Up Button Off Dimmer D...

Page 5: ...ArtNet DMX Mux24 Ethernet GND V IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 IN10 IN11 IN12 IN13 IN14 IN15 IN16 GND GND GND DMX DMX POWER 12 24V DC DMX OUT 5V IN17 IN18 IN19 IN20 IN21 IN22 IN23 IN24 Analog 0...

Page 6: ...curs via a web interface which can be called up via any web browser Set the IP with the IP Configurator The IP Configurator allows setting the IP Address and the net mask also if the PCs network setti...

Page 7: ...ich will be used for the web interface as well as for the ArtNet Set your computers network card to this IP range to access the IP address via the web browser The PCs network settings must be the IP A...

Page 8: ...IP Address that the assignment occurs clearly within the network Please use in accordance to the ArtNet Specification the IP Address 2 x x x or 10 x x x with the net mask 255 0 0 0 Any other IP addre...

Page 9: ...e regularly repeated output of values via ArtNet ArtNet Input Parameter The ArtNet input parameter specifies the values for the Art Net reception Net SubNet Universe Port are the Art Net parameter def...

Page 10: ...iring occurs with a switch or a button connect to GND as shown in the following outline For the LONG DISTANCE inputs we recommend cable lengths not exceeding 25m Depending on the environment and cable...

Page 11: ...The input field Parameter specifies which function is to execute e g which DMX channel is to set to which DMX value On the following pages the functions are described The processing of the input stat...

Page 12: ...LUE must be added to the DMX channel specification the specified value must lie in the range 0 to 255 If no value is specified 255 100 is used Example 1 222 set a single DMX channel to value 222 1 4 7...

Page 13: ...operated The dimming process finishes when the value 255 100 is reached during dimming up the value 0 0 during dimming down The dimming direction is changed when the input is not activated released B...

Page 14: ...n VALUE So for the specified channels the value will be added A possible configuration for an 8Bit binary input is as follows Inputs IN1 up to IN8 Outputs DMX channel 1 Configuration INPUT1 Mode Switc...

Page 15: ...for using as LONG DISTANCE digital inputs or analog inputs The inputs will be configured via the web interface The selection if the inputs should be used analog or digital occurs in on the site MAIN O...

Page 16: ...nection as digital input The wiring as LONG DISTANCE digital input occurs with a switch or button connect to GND as shown in the following picture GND V GND DMX DMX 5V IN17 IN18 IN19 IN20 IN21 IN22 IN...

Page 17: ...dding in the parameter input To adjust the assignment a parameter input according to the following structure is necessary CH INL INH OUTL OUTH CH DMX channel INL Input voltage LOW in V 0V up to 10V in...

Page 18: ...tputted linearly from 40 up to 180 From a voltage of 8V the DMX value 180 is outputted 10V 8V 2 5V 40 180 DMX UIN 54 2 5V 8V 180 40 Output occurs on DMX channel 54 Up to a voltage of 2 5V the DMX valu...

Page 19: ...X Mux24 can send a Wake On Lan WoL message via Ethernet when an input is activated selected For this the mode Button must be selected and as parameter WoL xx xx xx xx xx xx specified xx xx xx xx xx xx...

Page 20: ...via the timer so the single values must be entered separately with a comma For example a single channel with 100 or several channels with 100 110 120 Furthermore it is possible to specify to be outpu...

Page 21: ...l with 512 DMX Channels will be outputted The values of the DMX channels will be determined via the digital inputs and the configuration The configuration must occur via the web interface ArtNet DMX M...

Page 22: ...button Push button again and hold The green and yellow LED flashes now for ca 10 seconds alternately Release button meanwhile Now the Reset is in progress and the LEDs flashes 3x simultaneously as con...

Page 23: ...list Click Firmware Update Select Firmware file bin and confirm Please wait until the Update has finished If an error occurs during the update you can start from the beginning any time Alternatively y...

Page 24: ...ArtNet DMX Mux24 24 Equipment Top hat rail housing 1050 Power supply 12V Network cable...

Page 25: ...he EMC directive 2014 30 EU is necessary Disposal Electronical and electronic products must not be disposed in domestic waste Dispose the product at the end of its service life in accordance with appl...

Page 26: ...omponents according to the device paperwork This work can only be done by qualified personnel which read the full device paperwork and understand it Operating risk The Change or the operation under sp...

Page 27: ...itet vervielf ltigt oder verbreitet werden Alle in diesem Handbuch enthaltenen Informationen wurden mit gr ter Sorgfalt und nach bestem Wissen zusammengestellt Dennoch sind Fehler nicht ganz auszuschl...