background image

   EXAMPLE 2

DMX from DSC5V Wall Switch

DMX Source(s)

1, 2, 3, or 4

Gang/Switch

User DMX Lighting Console or

any DMX Generating Device

+9VDC

DMX 

Merger

INSTALLATION PRECAUTIONS:

DO NOT connect 120V to any of the switches or 
the circuit board. 

DO NOT connect 120V to any pairs of the data 
input/output cable/wire.

DMX data length is limited to 3000' depending on 
type of wire used.

Depending on type of wire used ensure there is a 
minimum of 8VDC present at the PCB with the unit 
powered.

Switch wiring gang boxes, and installation, 
are user (or electrician) required

3 Pairs needed:
(1) DMX Input Pair (optional 
for normal operation)
(1) +9VDC Power Wire
(1) DMX Output Pair

Recommended Wire: 
24 - 22 AWG or larger 
shielded with twisted pairs

 

 

 

 

Record Scene Button

Status & Record

Scene Indicator LED

Very soft brightness for 

undisturbed performances

1, 2, 3, or 4 Switch Options

9V

Power 

Supply

 

 

 

 

 

 

 

 

 

 

 

 

Cable or Wire 

Installed as needed: 

DMX to Switch 

(Optional once scenes are 

recorded)

, Power, and DMX from switch

400' or more depending on cable

- Belden 1420A or equivalent

DMX OUTPUT: To 
DMX Dimmers, 
Fixtures, etc.

DMX Merger

See ELM Video Technology’s 
line of DMX Merger products. 

Multiple merge options 

available.

   PCB WIRING DIAGRAM:

 

DMX From House Controller – pin 2

DMX From House Cont pin 3

DMX Out to Dimmers and Fixtures Shield/Drain

DMX Out to Dimmers and Fixtures – pin 2

DMX Out to Dimmers and Fi pin 3

Power Supply Ground

Power Supply Po9VDC

Factory Wired

DIP SWITCH SETTINGS

Reset Power to Activate

1: - TRANSITION / FADE RATE

 

ON - 5 SECONDS
OFF - IMMEDIATE

2: - DMX LOSS DIRECTIVE 

OFF - Transition/fade to switch/scene(s)
ON - DMX output is turned off 

3: - OVERRIDE / MERGE

OFF - DMX Input will OVERRIDE all switches 
ON - DMX will MERGE with enabled switches

4: Unused

Optional – Only needed if DMX loop through to 
merge or override is desired, or to record a scene

SCENE RECORD

With DMX Input and all switches off

1. Press and hold 3 sec [slow blink]
2. Turn on one switch to record [rapid blink]
3. Press and hold 3 sec [two confirm blinks]

  WIRE EXAMPLE USING CAT5 COLOR CODE

  

Switch Gnd

Shield

DMX + from Switch

Green/White

DMX - from Switch

White/Green

Power Supply Gnd to Switch

Orange/White

+5V to Switch

White/Orange

DMX + to Switch

Blue/White

DMX - to Switch

White/Blue

CONNECTION

WIRE

  

 

DSC5 - DMX Standard Wall Switch Controller User Guide

 

          

Pg 3

     

ELM Video 
Technology

DSC5-dmx-standard-wall-switch-controller-user-guide.lwp 

 www.elmvideotechnology.com     

copyright  

©

 2017  ELM Video Technology, Inc.