EXAMPLE 2
DMX from DSC5V Wall Switch
DMX Source(s)
1, 2, 3, or 4
Gang/Switch
User DMX Lighting Console or
any DMX Generating Device
+9VDC
DMX
Merger
INSTALLATION PRECAUTIONS:
DO NOT connect 120V to any of the switches or
the circuit board.
DO NOT connect 120V to any pairs of the data
input/output cable/wire.
DMX data length is limited to 3000' depending on
type of wire used.
Depending on type of wire used ensure there is a
minimum of 8VDC present at the PCB with the unit
powered.
Switch wiring gang boxes, and installation,
are user (or electrician) required
3 Pairs needed:
(1) DMX Input Pair (optional
for normal operation)
(1) +9VDC Power Wire
(1) DMX Output Pair
Recommended Wire:
24 - 22 AWG or larger
shielded with twisted pairs
Record Scene Button
Status & Record
Scene Indicator LED
Very soft brightness for
undisturbed performances
1, 2, 3, or 4 Switch Options
9V
Power
Supply
Cable or Wire
Installed as needed:
DMX to Switch
(Optional once scenes are
recorded)
, Power, and DMX from switch
-
400' or more depending on cable
- Belden 1420A or equivalent
DMX OUTPUT: To
DMX Dimmers,
Fixtures, etc.
DMX Merger
See ELM Video Technology’s
line of DMX Merger products.
Multiple merge options
available.
PCB WIRING DIAGRAM:
DMX From House Controller – pin 2
DMX From House Cont pin 3
DMX Out to Dimmers and Fixtures Shield/Drain
DMX Out to Dimmers and Fixtures – pin 2
DMX Out to Dimmers and Fi pin 3
Power Supply Ground
Power Supply Po9VDC
Factory Wired
DIP SWITCH SETTINGS
Reset Power to Activate
1: - TRANSITION / FADE RATE
ON - 5 SECONDS
OFF - IMMEDIATE
2: - DMX LOSS DIRECTIVE
OFF - Transition/fade to switch/scene(s)
ON - DMX output is turned off
3: - OVERRIDE / MERGE
OFF - DMX Input will OVERRIDE all switches
ON - DMX will MERGE with enabled switches
4: Unused
Optional – Only needed if DMX loop through to
merge or override is desired, or to record a scene
SCENE RECORD
With DMX Input and all switches off
1. Press and hold 3 sec [slow blink]
2. Turn on one switch to record [rapid blink]
3. Press and hold 3 sec [two confirm blinks]
WIRE EXAMPLE USING CAT5 COLOR CODE
Switch Gnd
Shield
DMX + from Switch
Green/White
DMX - from Switch
White/Green
Power Supply Gnd to Switch
Orange/White
+5V to Switch
White/Orange
DMX + to Switch
Blue/White
DMX - to Switch
White/Blue
CONNECTION
WIRE
DSC5 - DMX Standard Wall Switch Controller User Guide
Pg 3
ELM Video
Technology
DSC5-dmx-standard-wall-switch-controller-user-guide.lwp
www.elmvideotechnology.com
copyright
©
2017 ELM Video Technology, Inc.