LED BLINK RATES
Record Scene Error, button is pressed with a
switch on OR no DMX is present
3x Flicker
Respective scene has been recorded
2 Flashes
Record Scene Mode with the selected switch
to be recorded turn on
2x Blink
DMX Input data error has occurred since
powered OR unit is in Record Scene Mode
1x
Valid DMX is being received
ON
No DMX is being received
OFF
Description
Rate
SCENE RECORDING
1.
Insure a valid DMX signal is present indicated by the DMX input LED on.
2.
Preset a desired scene from the DMX lighting board or DMX generating device.
3.
Enter the PGM Scene Record Mode by press and holding the
Record
button for 3 seconds, the data LED will blink
at the 1x rate. Turn on only 1 switch that the scene is to be recorded to, the data LED will blink at the 2x rate. Press and
hold the
record
button for 3 seconds, the data LED will flash 2 times indicating the scene has been recorded.
To abort
recording, wait 20-30 seconds to allow the unit to time out.
Repeat steps to record each scene.
While in the scene record mode inactivity for 30 seconds will automatically cancel and exit.
DSC5 - DMX Standard Wall Switch Controller User Guide