background image

LED BLINK RATES

Record Scene Error, button is pressed with a
switch on OR no DMX is present

3x Flicker

Respective scene has been recorded

2 Flashes

Record Scene Mode with the selected switch
to be recorded turn on

2x Blink

DMX Input data error has occurred since  
powered OR unit is in Record Scene Mode

1x

Valid DMX is being received

ON

No DMX is being received

OFF

Description

Rate

          

SCENE RECORDING

1.

Insure a valid DMX signal is present indicated by the DMX input LED on.

2.

Preset a desired scene from the DMX lighting board or DMX generating device.

3.

Enter the PGM Scene Record Mode by press and holding the 

Record

 button for 3 seconds, the data LED will blink

at the 1x rate. Turn on only 1 switch that the scene is to be recorded to, the data LED will blink at the 2x rate. Press and
hold the 

record

 button for 3 seconds, the data LED will flash 2 times indicating the scene has been recorded. 

To abort

recording, wait 20-30 seconds to allow the unit to time out.

Repeat steps to record each scene. 

While in the scene record mode inactivity for 30 seconds will automatically cancel and exit.

  

 