Page 1: ...Media Spinner ORDERCODE 40169 ...

Page 2: ...on DMT for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant dutchmediatools info You can get some of the best quality best priced products on the market from DMT So next time turn to DMT for more great lighting eq...

Page 3: ...eterminations Rigging Description Features and Overview Backside Installation Set Up and Operation One Media Spinner Multiple Media Spinner DMX Protocol Control Panel Control Mode DMX addressing Functions control panel Master Slave mode Maintenance Replacing the Fuse Troubleshooting No Movement No Response to DMX Product Specifications ...

Page 4: ...at a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes DMT Media Spinner 1X 3m 3 pin IEC powercable User manual Contact Us General Information Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Sales Department 0031 45 5667701 Export Department 0031 45 5667706 Technical Support ...

Page 5: ...icular caution Never remove warning or informative labels from the unit Never use anything to cover the ground contact Never leave any cables lying around Do not insert objects into air vents Do not connect this device to a dimmerpack Do not switch the device on and off in short intervals as this would reduce the system s life Do not shake the device Avoid brute force when installing or operating ...

Page 6: ...rastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperature If your DMT device fails to work properly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your DMT dealer for service For ad...

Page 7: ...sing system The Media Spinner must never be fixed swinging freely in the room The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the Media Spinner always make sure that the area below the installation place is blocked and staying in the area is forbidden Flat surface Upside Down Against a wall This fixt...

Page 8: ...g Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER FASE N BLUE BLACK SILVER NUL YELLOW GREEN GREEN GREEN EARTH Make sure that the device is always connected properly to the earth ...

Page 9: ...ig 1 Fig 2 1 Display 9 3 pin DMX signal connector IN 2 Carrying handle 10 XLR In Out connector 3 XLR In Out connector 11 3 pin DMX signal connector OUT 4 RCA In Out connectors 12 On Off 5 IEC power connector 13 Base Fuse 5A Platform Fuse 10A 6 5 pin DMX signal connector IN 14 IEC power connector Fuse 7 5 pin DMX signal connector OUT 15 5 pin DMX signal connector OUT 8 RCA In Out connectors 16 3 pi...

Page 10: ...upply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Always disconnect from electric mains power supply before cleaning Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in always make sur...

Page 11: ...d properly Multiple Media Spinners Set Up DMX Set up Master Slave Set up Fig 3 Note Link all cables before connecting electric power Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX 512 controller or to run synchronized shows on two or more fixtures set to a master slave operating mode The combined number of channels required by all the fixtur...

Page 12: ...e turned by 540 and stopped at any position you wish Channel 2 Pan 16 bit Channel 3 Pan Speed Adjustment 0 Max Speed 1 255 Pan movement with decreasing speed Channel 4 Function 0 129 No function 130 139 PAN movement reset 140 209 No function 210 219 Platform power On 220 229 No function 230 239 Platform power Off 240 255 No function 0 255 Gradual adjustment Pan Speed from fast to slow ...

Page 13: ...dia Spinner should be 1 4 5 A005 the DMX address of the third Media Spinner should be 5 4 9 A009 etc Please be sure that you don t have any overlapping channels in order to control each Media Spinner correctly If two or more Media Spinners are addressed similarly they will work similarly For address settings please refer to the instructions under Addressing menu Controlling After having addressed ...

Page 14: ...ess DMX addressing 1 Press Mode until the display shows Run then press enter Press the Up Down button until the display shows DNCO and then press Enter 2 Press Up Down to select the required address press Enter to confirm 3 Press Choose the chosen address is shown on the display ...

Page 15: ...he desired function via UP DOWN buttons as tilt positive mode and as tilt Negative mode Press the ENTER button confirm the function and the display will shows DMX or MASTER SLAVE mode that you selected before Tilt mode Positive Tilt mode Negative MODE 5 Press the MODE ESC button until the display shows and set desired function via UP DOWN buttons as LED positive mode and as LED Negative mode Press...

Page 16: ... However you should keep the unit clean Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Do not use alcohol or solvents Keep connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing a Fuse Power ...

Page 17: ... Check that the unit is plugged into an appropriate power supply 2 The fuse Replace the fuse See page 14 for replacing the fuse No Response to DMX Response Suspect the DMX cable or connectors a controller malfunction a light effect DMX card malfunction 1 Check the DMX cable Unplug the unit change the DMX cable then reconnect to electrical power Try your DMX control again 2 Determine whether the co...

Page 18: ... off sporadically Possible bad lamp or fixture is overheating Lamp may be at end of its life X Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up X Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or bl...

Page 19: ...WxH Weight 17 2 kg Operation and Programming Signal pin OUT pin 1 earth pin 2 pin 3 Set Up and Addressing DMX Dip Switches DMX Channels 4 Signal input 3 pin XLR male Signal output 3 pin XLR female RCA In Out 85 MHz at Zin 75 ohms XLR In Out 85 MHz at Zin 75 ohms Maximum Load Capacity Platform 50 kg Design and product specifications are subject to change without prior notice Website www Highlite nl...

Page 20: ...2007 DMT ...