background image

1

1A. Description

DEL AOP Pro advanced oxidation process (AOP) products provide enhanced oxidation/disinfection capability by combining 

ozone and UV-C to form hydroxyl radicals. The optimized ozone/UV-C ratio results in hydroxyl radical creation that 

far exceeds any competitive AOP system. This is a game changer in disinfection, oxidation of organic and non-organic 

contaminants, destruction of biofilm and optimizing water clarity. 

AOP is compatible with all traditional sanitizers. These systems are cost effective to operate and maintain. AOP Pro products 

are NSF certified for supplemental disinfection of pools and spas.

AOP-PRO-50

AOP-PRO-50D

AOP-PRO-100

AOP-PRO-100D

FLOW

25-50 GPM

30-100 GPM

INLET/OUTLET

2 in

2 in

UV LAMP QTY 

2

4

PLC CONTROL

No

Yes

No

Yes

VOLTAGE

120 VAC

120 VAC

CURRENT

2.2 A

2.7 A

3.5 A

4.0 A

GAS FLOW RATE

20 CFH

40 CFH

Table 1: AOP Pro Sizing Chart

1B.Specifications

See 

Table 1

 for list of models and specs that apply to this manual. Images shown are model AOP-PRO-100D but manual 

instructions apply to all models, unless otherwise noted.

Figure 1: AOP Generator Overview

Water Inlet

Control Interface

(PLC Option Shown)

Water Outlet

Bonding Lugs

1. GENERAL INFORMATION

Summary of Contents for DEL AOP PRO 100

Page 1: ...4 2654 01 Rev A CMPCOMMERCIAL COM DEL AOP PRO 50 100 INSTALLATION INSTRUCTIONS PRODUCT MANUAL...

Page 2: ...high concentrations of ozone and long term inhalation of low concentrations of ozone can cause serious harmful physiological effects DO NOT inhale ozone gas produced by this device For your safety do...

Page 3: ...Shut Down 7 3D Water Chemistry 7 4 Maintenance Service 4A System Electromechanical Overview 9 4B Ozone System Maintenance 9 4C UV Reactor Service and Maintenance 10 4D PLC Memory Battery Backup Replac...

Page 4: ...re cost effective to operate and maintain AOP Pro products are NSF certified for supplemental disinfection of pools and spas AOP PRO 50 AOP PRO 50D AOP PRO 100 AOP PRO 100D FLOW 25 50 GPM 30 100 GPM I...

Page 5: ...r has a sustained 1 3 ppm free chlorine level 3 Test pool chemistry and adjust pH between 7 4 and 7 6 Adjust total alkalinity between 80 and 120 ppm 4 Run pool filtration continuously for 24 hours pri...

Page 6: ...mportant wiring information 2D 1 Main Power Connect the AOP Pro so that it operates simultaneously with the pool pump An electrical junction box and wires are provided on the left wall of the enclosur...

Page 7: ...return of the pool Use the fittings provided in the parts kit to connect the AOP Pro inlet and outlet to the plumbing The included injector and degas management system components should be installed i...

Page 8: ...upplied and the remote start contacts are closed 2 FLOW This indicator will illuminate when the water flow has been established 3 UV C This indicator will illuminate when the UV system is active 4 OZO...

Page 9: ...rs remaining on the countdown timers are used to determine service messaging and alert reminders More than 10 remaining no banner message 10 remaining SERVICE SOON banner message 5 remaining SERVICE R...

Page 10: ...on key Banner Message 7 Banner Message Located on the top of all screens this field will provide messages and alerts relative to the real time operation of the unit 3C System Shut Down Followed for se...

Page 11: ...ter Degas Valve Water Out Mixing Degas Vessel MDV UV Reactor Air Check Valve Flow Switch Air Filter Outlet Union Thermal Protection Location Not Shown Inlet Union Ballast Ozone Power Supply Ozone Cell...

Page 12: ...destruct Ozone enriched water then exits the mixing degas vessel MDV and enters the input of the AOP Pro 4A 5 UV Reactor There are two lamps in each UV reactor of the AOP Pro powered by an energy effi...

Page 13: ...decreased based on the condition of the quartz tubes or observed water conditions 4C 1 UV Lamp Removal 1 Remove the UV service access panel from the top of the enclosure NOTE The AOP Pro will not ope...

Page 14: ...the sealing O ring from the quartz tube and set aside 8 Wipe all residue from the quartz tube If calcium deposits are encountered use a mild solution 4 1 of water and muriatic acid available at pool s...

Page 15: ...main inlet and outlet fittings on the AOP Pro 4 Turn the circulation pump ON and check the quartz tube seals for leaks 5 Turn the circulation pump OFF once you have confirmed that the quartz tubes ar...

Page 16: ...performed annually 4E Winterizing If the pool will be shutting down for the winter months and the AOP Pro will remain exposed to freezing temperatures the unit must be drained to prevent freeze damag...

Page 17: ...wired and operating properly Symptom WAITING ON SYSTEM FLOW message on HMI screen or FLOW indicator not lit 1 Insufficient flow through AOP Pro a Verify that the main system pump is running properly...

Page 18: ...CEMENT INTERVAL PLC MEMORY BACKUP BATTERY included with PLC option only 5 1402 Annually AIR FILTER ELEMENT 7 1120 2250 Hours AIR CHECK VALVE 7 1140 01 8750 Hours OZONE CHECK VALVE 8 0330 8750 Hours OZ...

Page 19: ...ro Pressure Drop Characterization NOTE Tested on simulated recirculation system using a variable speed pump No back pressure added Actual results will vary depending on pump and plumbing variables APP...

Page 20: ...the inlet outlet unions b Flow the cleaning solution from bottom to top 2 When cleaning is complete drain the AOP Pro completely from the inlet union and run the pool system immediately for an extend...

Page 21: ...Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date __________...

Page 22: ...19 NOTES...

Page 23: ...20 NOTES...

Page 24: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW CMPCOMMERCIAL COM 1021ab...