LCD Keypad Installation Guide
LCD Keypad Installation Guide
17
DEGRADED MODE
RELAY ALWAYS OFF
Degraded Mode
(7063/7063A, 7073/7073A, 693/793 only)
This option defines the relay action when
communication with the panel has not occurred
for five seconds. Press any top row Select key
to display CHOOSE ACTION. The default is Relay
Always Off.
CHOOSE ACTION
OFF SITE ANY ON
Choose the Degraded Mode Action required.
Press the first Select key to choose OFF
[Default] (Relay Always Off)
— The relay does not turn on when any
Wiegand string is received.
Off does not affect any REX operation.
Press the second Select key to choose SITE
(Accept Site Code)
— Door access is granted when the
Wiegand site code string received
matches any site code programmed at
SITE CODE ENTRY.
For details refer back to the REQUIRE
SITE CODE option.
Press the third Select key to choose ANY
(Any Wiegand Read)
— Door access is granted when
any
Wiegand string is received.
Press the fourth Select key to choose ON
(Relay Always On)
— The relay is always on.
CHOOSE ACTION
LAST
Press the COMMAND key to display the next
action.
Press the first Select key to choose LAST
(Keep Last State)
— The relay remains in the same state
and does not change when
communication is lost.
After choosing the action, DEGRADED MODE and the
newly defined action display. Programming is now
complete.