Identify Unknown Zones
The Zone Finder feature built into XR150/XR550 Series panels is a diagnostic function that
allows an installer to identify unknown zones in the system. To identify a zone, fault the
Radionics point to display the equivalent DMP zone number at the keypad. Refer to the
panel programming guide for additional information on this feature.
1.
Reset the panel, enter
2313
(DIAG), and press CMD.
2. Press CMD to display
ZONE FINDER
. Press any select key or area. The display
changes to
FAULT ZONE
.
3. Short the zone. The next zone on the system that changes from a normal to an
open or shorted state is displayed as
ZONE NO: * * *
. To continue to the next zone,
press the back arrow key and repeat step 3 until all zones have been identified.