734INT Installation and Programming Guide | Digital Monitoring Products, Inc.
Install the 333 Suppressor
Use the included 333 suppressor with
the 734INT to suppress any surges
caused by energizing a magnetic lock
or door strike.
Install the 333 across the 734INT C
(common) and NO (normally open) or
NC (normally closed) terminals.
If the device being controlled by the
relay is connected to the NO and C
terminals, install the suppressor on the
NO and C terminals.
Conversely, if the device is connected
to the NC and C terminals, install the
333 Suppressor on NC and C terminals.
The suppressor wire is non‑polarized.
Install the suppressor as shown in
4
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
734INT Interface Module
Figure 7: 333 Suppressor
Installation on the 734INT