10
734B Installation and Programming Guide | Digital Monitoring Products, Inc.
Zone 1
Zone 2
Zone 3
Zone 4
1
2
3
4
5
6
7
8
10 11 12 13 14
9
LC
AS
RED WHT GRN BLK
Z1
Z2 Z3
Z4+ Z4–
RA
GND
GND
1K EOL
1K EOL
1K EOL
1K EOL
Figure 8: 734B Zone Terminal Wiring
Zone 3 can also
be wired normally
closed with an
in‑line 1K Ohm
resistor
ZONE #
RECOMMENDED DEVICE
1
Any burglary device
2
Door Contact
3
REX (PIR or Button)
4
Any device
Table 1: 734B Zone Uses