Digital Monitoring Products, Inc. | 734B Installation and Programming Guide
7
Isolation Relay (optional)
The Form C relay can control a device that draws less than 10 Amps of current. If a
device draws more than 10 Amp of current, or the sum of all devices controlled by
the Form C relay exceeds 10 Amps, an isolation relay must be used. Refer to Figure 5
and Figure 6 for isolation relay wiring.
3
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
Model 333
Suppressor
Normally Open
–
+
Magnetic Lock
–
+
Isolation Relay
To Panel
Keypad Bus
12/24 VDC
Power
Supply
NC
C
NO
Figure 5: Magnetic Lock with an Isolation
Relay
RED
PROG
J2
RED
J5
RED
KYPD IN
J4
KYPD OUT
J1
DATA
XMT LED
WIEGAND
READ LED
RELAY
ON
NC
C
NO
GRN
YEL
RED
+ –
Piezo
Model 333
Suppressor
Normally Open
–
+
DC Door Strike
–
+
Isolation Relay
To Panel
Keypad Bus
12/24 VDC
Power
Supply
NC
C
NO
Figure 6: Door Strike with an Isolation
Relay
Summary of Contents for 734B
Page 1: ...INSTALLATION AND PROGRAMMING GUIDE 734B Access Control Module...
Page 2: ......
Page 4: ......
Page 34: ...30 734B Installation and Programming Guide Digital Monitoring Products Inc...
Page 35: ...Digital Monitoring Products Inc 734B Installation and Programming Guide 31...
Page 36: ...LT 1952 20055 2020 Digital Monitoring Products Inc...