734B Installation and Programming Guide     |     Digital Monitoring Products, Inc.

KYPD IN / KYPD OUT Connections

• 

KYPD IN (Keypad In): Receives and transmits data to the panel Keypad 

bus/AX‑Bus.

• 

KYPD OUT (Keypad Out): Receives and transmits data out to other keypad(s) or 

module(s). Install a dual‑connector harness to allow connection to other devices 

up to the maximum number of devices supported.

When the 734B is powered from 24 VDC, do not connect devices to KYPD OUT header.

Status LEDs

The 734B board contains three status LEDs.

• 

The Red LED turns on for the same duration as the door strike relay.

• 

The Yellow LED turns on for one second to indicate receipt of a valid input.

• 

The Green LED indicates data sent to the panel.

Summary of Contents for 734B

Page 1: ...INSTALLATION AND PROGRAMMING GUIDE 734B Access Control Module...

Page 2: ......

Page 3: ...ram BINs as User Codes 18 Program BINs Locally 18 Program the Module in Standalone Mode 19 TABLE OF CONTENTS Programming Reference 20 Program Start Display 20 Serial Number 20 Initialization Option 20...

Page 4: ......

Page 5: ...control capability of DMP Panels The module is designed specifically to support BIN tables for the banking industry For example use the 734B to control access to ATM vestibules with magstripe readers...

Page 6: ...34B or from XR150 XR550 Series panels Keypad In and Out Connections The keypad in KYPD IN connection receives and transmits data to the panel keypad bus or AX Bus The keypad out KYPD OUT connection re...

Page 7: ...READ LED RELAY ON NC C NO GRN YEL RED ON Piezo 1 2 3 4 5 6 7 8 10 11 12 13 14 9 LC AS RED WHT GRN BLK Z1 Z2 Z3 Z4 Z4 RA GND GND KYPD IN RED Door Relay Terminal Inputs Status Indicator Outputs Zones To...

Page 8: ...ple mounting holes that allow you to mount the module on a single gang switch box DMP recommends mounting the 734B near the protected door See Figure 2 for mounting hole locations on the housing base...

Page 9: ...nd contacts are rated for 10 Amps resistive at 12 24 VDC When connecting multiple locks to the Form C relay the total current for all locks cannot exceed 10 Amps If the total current for all locks exc...

Page 10: ...r module s Install a dual connector harness to allow connection to other devices up to the maximum number of devices supported When the 734B is powered from 24 VDC do not connect devices to KYPD OUT h...

Page 11: ...ation relay wiring 3 RED PROG J2 RED J5 RED KYPD IN J4 KYPD OUT J1 DATA XMT LED WIEGAND READ LED RELAY ON NC C NO GRN YEL RED Piezo Model 333 Suppressor Normally Open Magnetic Lock Isolation Relay To...

Page 12: ...y closed terminals If the device being controlled by the relay is connected to the NO and C terminals install the suppressor on the NO and C terminals Conversely if the device is connected to the NC a...

Page 13: ...3 Zones 2 and 3 can also be used for access control with zone 2 providing a bypass feature and zone 3 providing request to exit functionality Use the supplied 311 1K Ohm End of Line EOL resistors on...

Page 14: ...10 11 12 13 14 9 LC AS RED WHT GRN BLK Z1 Z2 Z3 Z4 Z4 RA GND GND 1K EOL 1K EOL 1K EOL 1K EOL Figure 8 734B Zone Terminal Wiring Zone 3 can also be wired normally closed with an in line 1K Ohm resisto...

Page 15: ...ire is ground The wire colors may be different depending on the reader being installed Refer to the literature provided with the reader for wire coding wire distance cable type such as shielded and ot...

Page 16: ...e Annunciation provides an unsupervised switched ground for a remote annunciator that turns on when the Zone 2 Bypass timer expires Connect the wire from the RA Terminal to a remote annunciator The re...

Page 17: ...Programming Guide 13 Figure 9 Magstripe Reader Wiring 1 2 3 4 5 6 7 8 10 11 12 13 14 9 LC AS RED WHT GRN BLK Z1 Z2 Z3 Z4 Z4 RA GND GND J3 ON Red 12 24VDC Black GND Orange Brown Yellow Green Data 0 Whi...

Page 18: ...panel set it to address 2 or higher 7 Keypad Bus Addresses Explained Each keypad bus address can accommodate one door output and four expansion zones A 734B with an address of 2 on the keypad bus wou...

Page 19: ...ld represent door 501 and zones 501 504 A 734B with an address of 2 on AX500 would represent door 505 and zones 505 508 A 734B with an address of 1 on AX700 would represent door 701 and zones 701 704...

Page 20: ...13 716 813 813 816 913 913 916 5 51 54 517 517 520 617 617 620 717 717 720 817 817 820 917 917 920 6 61 64 521 521 524 621 621 624 721 721 724 821 821 824 921 921 924 7 71 74 525 525 528 625 625 628 7...

Page 21: ...ccur You can also program the 734B from an XR150 XR550 Series panel If you choose to program the 734B from the panel all future programming should be performed through the panel The panel s programmin...

Page 22: ...llows you to program the 734B as a standalone access control module and allows up to 64 BINs For more information about programming options refer to Programming Reference Program BINs as User Codes Pr...

Page 23: ...N codes are processed locally 4 Program the 734B serial number as a user code in the panel The 734B processes all valid access locally and sends the serial number to the panel as a user code Program t...

Page 24: ...an set the 734B module programming memory back to factory defaults Press any select key or area to enter the Initialization Menu Initialize Confirm Option After selecting YES to clear the Access Optio...

Page 25: ...one 2 When the onboard Form C relay activates and the user opens the door connected to zone 2 the zone is delayed for the number of seconds programmed in ZONE 2 BYPASS TIME allowing the user to enter...

Page 26: ...ting NO leaves the relay on when zone 2 changes state Turning off the relay allows a long strike time to be automatically ended upon zone 2 change and relocks the door The default is NO Note If using...

Page 27: ...wiring details refer to Figure 8 Activate Strike Relay and Bypass Wire zone 3 as normally open with a 1K Ohm EOL resistor When zone 3 shorts the onboard Form C relay activates for the programmed numbe...

Page 28: ...his does not affect remote annunciator open collector RA operation The default is NO BIN Code Length Enter the length of the BIN code Range is 1 8 The default BIN code length is 6 Enable Local Process...

Page 29: ...ay remains on for the door strike duration but turns off at the end of the door strike timer Press the second select key or area to choose BIN Accept BIN Code Door access is granted when the received...

Page 30: ...ays with no timeout while the keypad remains connected to the 734B module after programming is finished After five seconds the 734B module piezo continually sounds if the keypad remains connected and...

Page 31: ...ckup Note Each panel allows a specific number of supervised keypads Add additional keypads in the unsupervised mode Maximum distance for any one bus circuit length of wire is 2 500 ft regardless of th...

Page 32: ...IONS Primary Power 8 5 VDC to 28 5 VDC Current Draw Standby 240 mA Includes 200 mA for magstripe reader Alarm 260 mA Includes 200 mA for magstripe reader Form C Relay 35 mA at 12 24 VDC Zones 5 VDC 2...

Page 33: ...ide 29 READERS The 734B Access Control module has been tested with various magnetic stripe card readers To be compatible magstripe readers must use Clock and Data output in ABA Track 2 format Verify a...

Page 34: ...30 734B Installation and Programming Guide Digital Monitoring Products Inc...

Page 35: ...Digital Monitoring Products Inc 734B Installation and Programming Guide 31...

Page 36: ...LT 1952 20055 2020 Digital Monitoring Products Inc...

Reviews: