7
USE THE KEYPAD FOR ACCESS CONTROL
Card Readers
When a proximity credential is presented to an internal or external reader, a beep
tone is heard and the Power/Armed LEDs blink. This provides an audible and visual
acknowledgment of the credential read.
Internal Access Control Reader
The 7063/A, 7073/A, 7163, and 7173 keypads provide a built-in proximity card
reader that is compatible with most standard 125Khz Prox credentials available
from DMP and HID (1300 Series). DMP Keypads are not compatible with iClass
or other non-HID credentials. There are custom and non-standard credentials
from HID that are not compatible with DMP proximity keypads. If you are using
HID cards that have not been purchased directly from DMP, it is recommended to
thoroughly test the application fully before installation. DMP does not guarantee
compatibility with credentials not purchased from DMP. For listed access control
applications, the keypad must be installed within the protected area.
External Access Control Reader
To accept Wiegand data input from other external card readers, connect a 12VDC
external reader to the 7073/A and 7173 keypad. Connect the red and black power
wires from the reader to the power wires from the panel. These connect in parallel
with the keypad power wires. Connect the Reader (Data 1) wire to the white wire
on the 5–wire keypad harness. Connect the Reader (Data 0) wire to the green/
white wire on the 5–wire keypad harness. See Figure 4.
1K EOL
1K EOL
1K EOL
1K EOL
Green/White
– Connect Reader Data 0
White
– Connect Reader Data 1
Orange
– Door Strike N/O
Gray
–
Door Strike C
Violet
–
Door Strike N/C
Yellow/White
White/Yellow
Orange White
White/Orange
Red/White
White/Red
Brown/White
White/Brown
Black
– Ground
Green
– Receive Data
Yellow
– Send Data
Red
– Keypad Power
– Zone 4
– Zone 3
– Zone 2
– Zone 1
ExternalReader/Door Strike
7073/7073A, 7173 Keypads
All Keypads
Zones 1-4
7070/7070A, 7073/7073A, 7170/7173 Keypads
Surface and Backbox
Mounting Holes
Combined 4-square
and 3-gang switch box
Mounting Holes
Surface and Backbox
Mounting Holes
*All zones are supervised and suitable for fire applications.
*Maximum zone line impedence is 100 Ohms.
*Ground fault detected at 1420 Ohms or less.