22
Site Code Position
(7063/A, 7073/A, 7163, 7173)
Enter the site code start position in the data string. Press any
select key to enter a number between 0-255. Default is 1.
Site Code Length
(7063/A, 7073/A, 7163, 7173)
Enter the number of characters the site code contains. Press
any select key to enter a number between 1-16. Default is 8.
User Code Position
(7063/A, 7073/A, 7163, 7173)
Define the user code start bit position. Press any select key to
enter a number between 0-255. Default is 9.
User Code Length
(7063/A, 7073/A, 7163, 7173)
Define the number of user code bits. Press any select key
to enter a custom number. Custom numbers can only be a
number between 16-40. Press CMD to save the entry. The
default is the DMP value of 16.
Require Site Code
(7063/A, 7073/A, 7163, 7173)
Press the top row select key under YES to use a site code and
press CMD to view the site code entry display. Default is NO.
Door access is only granted when any one site code
programmed at the SITE CODES entry option matches the site
code received in the Wiegand string. You can program up to
8 three-digit site codes. A card with a site code greater than
three digits cannot be used.
SITE CODE
POSITION: 1
SITE CODE
LENGTH:
8
USER CODE
POSITION: 9
USER CODE
LENGTH:
16
REQUIRE SITE
CODE: NO YES