Digital Monitoring Products, Inc | 7000INT Series Installation and Programming Guide
17
The keypad provides a bypass-only option for REX on
Zone 3. When Zone 3 opens from a normal state, only a
bypass occurs: the on-board relay does not activate. This
bypass-only option uses two methods of REX. The first REX
device provides the programmed bypass entry/exit timer.
The second REX unlocks the door.
Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. Range is
5-250 seconds. Press any select key to clear the keypad
display and enter the number of seconds. The default is
5
.
Arming/Disarming Wait Time
Select the number of seconds (0-9) the keypad should
wait to arm and disarm when an Area system displays
ALL? NO YES
or a H/S/A system waits during arming only.
If
NO
or
YES
, or
HOME
,
SLEEP
, or
AWAY
is not manually
selected before the delay expires, the keypad automatically
selects
YES
or
AWAY
. Select zero (0) to disable this feature.
The delay also occurs when a credential is presented for
arming the H/S/A system. Default is
2
.
ZONE 3 REX STRIKE
TIME:
5
ALL?: NO
YES
DELAY:
2
Summary of Contents for 7000INT Series
Page 2: ......
Page 41: ......
Page 42: ......
Page 43: ......
Page 44: ...LT 0883INT 19081 1 01 2019 Digital Monitoring Products Inc ...