background image

MPI

Connection 

symbols

Lift car alarm button

DMG multiplepurpose position indicator/inductive ring

Slave
Devices :

Shaft = Shaft  •  Floor = Main Floor
Car TOP = Top of car  •  Car BOTTOM = Car bottom

Machine Room = Machine Room autodialler
Car slave device = Car slave device

2.6 - Advanced connections (EN 81-28 norm)

Signals related to the events “car in unlocking position with cabin and landing door open” and “car 
running” when available from controller (or from any other device in the installation) can be used to 
filter undue alarms (§ 4.2.1 in EN 81-28 norm). For this purpose, connect t

 

Full compliance to EN81-28 norm shall be achieved by connecting AMIGO Telephone to an external 
Rescue Service (Call Center or the like) which shall manage and record the following operating tests 
of the Alarm System:

2.6.1 - Cyclical operating test (§ 4.2.1 in EN 81-28 norm)

The Alarm System shall simulate an alarm event and establish a communication with the Rescue 
Service at least every 72 hours (3 days). AMIGO Emergency Telephone allows this feature through 
input N.6 (CYCLICAL TEST). If this input is closed (bridged), an automatic service call with the 
message (”Regular Operation”) is passed every 72 hours. 

2.6.2 - Emergency power supply test (§ 4.1.3 in EN 81-28 norm)

No alarm shall be lost even in case of power failure. If the Alarm System has a rechargeable battery, an 
alert message shall be sent when capacity is lower than what needed to provide 1 hour of normal 
operation to the system in case of power failure. 
To comply with this requirement, the external Battery Charger ETS8128CH (optional) must be added 
to AMIGO Emergency Telephone. Output n.5 of the charger must be connected to input n.5 (LOW 
BATTERY CHARGE) of the Emergency Telephone. 
When the contact is activated, AMIGO Emergency Telephone sends a service call with the   “Low 
battery charge” message. When the contact reopens, a service call with the “Regular operation” 
message is sent.

NOTA: Battery Charger ETS8128CH checks battery status every 24 hours only with power supply. In 
case of black out the low battery output is not activated to avoid the risk that service calls further affect 
the battery charge.

he potential-free contact to 

the ALARM FILTER input of the Emergency Telephone.

18

15

3.4 - Stand by

NEXT-WRITE-OK-ESC 

Stand by menu appears on system startup and upon exit from programming mode. It shows the 
software release stored in the Emergency Telephone. 
Press 

keys and press 

"1 2 3 4" 

and then "

OK

" to enter programming mode.

3.5 - Numbers from 1 to 6

1st number” to “6th number”)

If 

OK 

is not pressed within 30 seconds, the new number is cancelled and 

the system goes back to Stand by).

The phone number contained in the chosen slot is shown on the bottom left side of the display. Press 

WRITE

 to modify it (if no number is present, the display shows “none”). 

The “1st number” must always be present, otherwise the alarm cycle cannot start (if no “1st number” is 
entered, "no tel num" will be showed in the top right side of the Stand by screen).   

simulate the “Regular operation” service call. Press “

2

” to forward the call and “ 

*

 ” to close it.

This menu enables users to store the phone numbers to be called during the alarm cycle (up to 6 
numbers can be stored) . 
To enter/modify a phone number, scroll the menu with the 

NEXT 

key until the desired position is 

reached (slots from “

, press the

 WRITE 

key, type in the phone number 

and then press 

OK

 to save it   (

From each slot it is possible to:
- manually connect to the phone line to check its availability. Press “

1

 

to connect to the line and “

0

” to 

disconnect;

Xxx number

Next phone number

Xxx number

(MAX di 16 digits)

ESC

NEXT

WRITE

DMG
Amigo XX      vX.X

Stand by

DMG
Amigo XX      vX.X

stops the service call

close the phone line (if open)

14

connects to the phone line

1

0

*

2

simulate the service call “Regular operation”

to store

OK

ESC

NEXT

Next phone number

Stand by

DMG
Amigo XX      vX.X

AMIGO

Emergency telephone

ETS8128CH

Alim 230Vac

1 (power + 12V)

2 (power - 12V)

5 (insufficient charge)

Fusibile rete

charger status LED 

Internal battery contact

LE

D

BA

TT

ER

Y

Li

g

h

O

F

F

S

lo

w

 b

li

n

k

in

g

N

o

rm

a

b

li

n

k

in

g

F

a

st

 b

li

n

k

in

g

Li

g

h

O

N

In

su

ff

ic

ie

n

b

a

tt

er

ch

a

rg

e

or

 b

a

tt

er

n

ot

 c

on

n

ec

te

d

5

N

po

w

er

 s

up

pl

an

B

AT

TE

R

O

K

S

ta

n

d

a

rd

 c

h

a

rg

e

F

a

st

 c

h

a

rg

e

N

o

 p

o

w

e

su

p

p

ly

 a

n

d

B

A

TT

E

R

Y

 n

o

ch

a

rg

e

d

2

3

0

V

A

C

1

2

V

 D

C

1

2

5

B

at

te

ry

 c

ha

rg

er

ET

S8

12

8C

H

Power supply

230Vac

Output

12Vdc 300mA isolated through transformer

Battery

12V 250mAh NiMh

Autonomy

stand-by 15H / conversation 2H

“Insufficient charge” ouptut

open collector max 20mA

Battery test

every 24 hours

Power connections

screw terminals 2P  5mm

Output connections

 3P  5mm

Power input protection 

0,5 A 5x20mm fuse

12v out

1A fuse self repairing

screw terminals

put protection

AMIGO

Emergency telephone

Summary of Contents for amigo

Page 1: ...51 Fax 39 0693025240 info dmg it www dmg it NOTE Leave this document close to the emergency telephone after installation Installation manual Vers 1 2 English AMIGO ETS8128CM ETS8128MR ETS8128CS Emergency Telephone EN 81 28 compliant AMIGO 93010044_E_amigo_060324 0_EN cdr ...

Page 2: ...receiver Feeder battery charger optional Top bottom of car slave device SYSTEM COMPONENTS Code Description AMIGO Emergency telephone Car master device ETS8128CM ETS8128MR ETS8128CS ETS8128SL CITCOC ETS8128CH NOTES AMIGO Emergency telephone ETSGSM GSM Module ...

Page 3: ...nfiguration EN 81 28 norm 4 DEVICE configuration EN 81 28 norm Function keys Troubleshooting page 4 page 4 Available s page 4 Basic alarm cycle setting for calls towards standard phone numbers Without DTMFcommunication protocol page 5 calls towards standard phone numbers Without DTMFcommunication protocol page 6 Basic alarm cycle setting for calls towards service center page 7 1 7 calls towards se...

Page 4: ... ETS8128CM s 2 1 and 2 2 Machine room Master device code ETS8128MR ETS8128CS s 2 3 Technical features Power supply 12Vdc Absorption in stand by Absorption during the call cycle 150mA ptional Feeder battery charger code ETS8128CH Main functions phone numbers for emergency calls phone number dedicated to service calls Site identification message Possibility of storing two customized messages associa...

Page 5: ...t to enable the SITE IDENTIFICATION message deselect the message forward option see 3 11 and disregard 8 9 The first phone number must be always recorded otherwise the alarm cycle will not be triggered 3 14 Call delay When set on No delay the autodialler starts the alarm cycle immediately upon activation of the alarm pushbutton positioned on one of the alarm devices When set on 5 sec delay the aut...

Page 6: ... see 3 10 the Emergency Telephone sends 5 tones to the operator If the operator presses the key conversation time is extended if the operator presses the key the telephone disconnects the telephone line the yellow alarm sent LED switches off and the green alarm received LED switches on The message Wait for call will appear on the display When the Emergency Telephone is in Wait for call status dura...

Page 7: ...on either ANEP or Ademco or Scantronics see 3 13 the autodialler does not send voice service messages but dialogues with service centers exclusively through DTMF tones In such case an ID Number must be entered into the autodialler The ID number will be sent to the service center and will allow the unique identification of the installation which generated the emergency call To set the ID Number pre...

Page 8: ...lephone disconnects the telephone line the yellow alarm sent LED switches off and the green alarm received LED switches on The message Wait for call will appear on the display When the Emergency Telephone is in Wait for call status duration can be set by the client see 3 8 the external operator can connect to the site by dialing its phone number When the communication is established the Telephone ...

Page 9: ... 1 0 Stand by DMG Amigo XX vX X ESC Stand by DMG Amigo XX vX X 3 11 Voice messages Site Identification msg id tel Low battery charge msg batt ko Regular operation msg tel ok The Site Identification message is sent to phone numbers stored in the memory and is passed three times at the beginning of the emergency call To stop message reproduction and start two way communication the external operator ...

Page 10: ...a 9 WRITE NEXT ESC OK to store Stand by DMG Amigo XX vX X Conv 1 9 min If no key is entered within 30 seconds the autodialler will automatically get back to stand by Stand by DMG Amigo XX vX X ESC NEXT Messages AMIGO Emergency telephone Communication network Call Center Operator Emergency Telephone code ETS8128CM Power supply with 12V battery code ETS8128CH optional The emergency call is made by p...

Page 11: ...e or Pulse ESC NEXT WRITE If no key is entered within 30 seconds the autodialler will automatically get back to stand by 0 1 OK to store ESC NEXT Conv 1 9min Pulse Tone Stand by DMG Amigo XX vX X Stand by DMG Amigo XX vX X AMIGO Emergency telephone 2 3 4 DEVICE configuration EN 81 28 norm Interphone code CITCOC Machine Room device code ETS8128MR Top of car device code ETS8128SL Shaft device code E...

Page 12: ...lls set on either ON or OFF by pressing on the autodialler by pressing 8 on the remote phone device see 1 8 From Wait for call status a new alarm cycle can be triggered To set Incoming calls press WRITE to access programming mode then press 1 to set ON or 0 to set OFF Press OK to store the setting If OK is not pressed within 30 seconds the setting is cancelled and the system goes back to Stand by ...

Page 13: ...hone microphone ETS8128CM device Common for signals ETS8128MR device Common for interphone Telephone line Terminal description ETS8128CS Alarm sent signal output 12V 20mA Alarm received signal output 12V 20mA Common for signals 12V DC 1 2 3 4 5 6 7 8 9 10 11 12 RE SET 72h COM 13 14 6 2 1 CITCOC 12V DC 1 2 3 4 5 6 7 8 9 10 11 12 RE SET 72h COM COM 13 14 ETS8128CM ETS8128MR 1 2 3 COM ETS8128CS No At...

Page 14: ...ithin 30 seconds the autodialler will automatically get back to stand by Only for 3 Device configuration AMIGO Emergency telephone Connections for controller ETS8128CM in SINGLE DEVICE and 3 DEVICE configurations POWER SUPPLY 12 V DC ALARM FILTER ALARM OFF LOW BATTERY CHARGE CYCLICAL TEST COMMON INPUTS ALARM SENT SIGNAL 12V ALARM RECEIVED SIGNAL 12V COMMON FOT SIGNALS TELEPHONE LINE FEEDER 12 V DC...

Page 15: ...T WRITE OK ESC Stand by menu appears on system startup and upon exit from programming mode It shows the software release stored in the Emergency Telephone Press keys and press 1 2 3 4 and then OK to enter programming mode 3 5 Numbers from 1 to 6 1st number to 6th number If OK is not pressed within 30 seconds the new number is cancelled and the system goes back to Stand by The phone number containe...

Page 16: ... When indicated in the menu enables the relevant option No Attempts Incoming calls Number of attempts see 3 7 Incoming calls see 3 8 Conv 1 9 min Conversation time see 3 10 Note Low battery charge and Regular operation messages are sent exclusively to Service call no phone number NEXT NEXT 1 2 3 4 5 6 Stand by see 3 4 DMG 4 NEXT WRITE OK ESC 3th number 4th number Phone Number 3 see 3 5 Phone Numbe...

Reviews: