background image

 

DER-S0080A 

Rev. 12©1999 - 2011 DMC Co., Ltd. 

ATP/AST Series Product Specifications

5. Handling Notes 

5-1. Precautions 

§ This product is intended for use in standard applications (computers, office automation, and other office 

equipment, industrial, communications, and measurement equipment, personal and household devices, 
etc.) Please avoid using this product for special applications where failure or abnormal operation may 
directly affect human lives, or cause physical injury or property damage, or where extremely high levels 
of reliability are required (such as aerospace systems, vehicle operating control, atomic energy controls, 
medical devices for life support, etc.). 

 

5-2. Handling Notes 

§ Do not depress or scratch the product with any object with a sharp edge or end. 
§ Do not forcibly bend or fold the product. 
§ When the product is stored, make sure it is packed in a packing box and stored in a storage temperature 

range, eliminating any outside load. 

§ Do not use or store the product under a condition where the product will be exposed to water, organic 

solution or acid. 

§ Do not use the product under the direct sunlight. 
§ Do not disassemble the product. 
§ When you handle the product, Hold the product by its body. Do not hold by the tail. 
§ Clean the product with a soft cloth or a soft cloth with neutral detergent or alcohol. When contaminated 

by chemicals, wipe them off immediately with caution not to cause injury to human body. 

§ The edge of the glass is not rounded and may cause injury. 
 

5-3. Construction Notes 

§ The environmental specifications, mechanical characteristics, and electrical characteristics are only 

applied to the Active Area.   

§ Do not use the touchscreen when the condensation occurs. The condensation inside of the touchscreen 

is a natural phenomenon and should disappear after the touchscreen is warmed up.   

 

5-4. Electrical & Software Notice 

The best performance can be obtained when used with the original analog resistive touchscreen controller, 
“TSC-10” Series. If the touchscreen controller or controller software is to be developed by the customer, 
please note the following: 
§ There is a contact resistance between the top and bottom electrodes and it changes by the pressure of a 

finger or a pen. The data must be read after the contact resistance becomes stabilized. 

§ The terminal resistance of the analog resistive touchscreen varies by the individual, time, and 

environment. The controller software must have the calibration function to adjust the input position and 
the display position. 

§ The analog resistive touchscreen outputs 2 point input as 1 point in between the 2 points. The controller 

software must not be designed to have the 2 point input function. 

§ For drawing applications, the line may be intermittent when the pen comes on the dot spacers. A 

software compensation is needed. 

 

Summary of Contents for Analog Resistive Touchscreen ATP/AST Series

Page 1: ...Analog Resistive Touchscreen ATP AST Series Product Specifications...

Page 2: ...n 5 2 2 Environmental Specifications 5 2 3 Mechanical Characteristics 5 2 4 Electrical Characteristics 6 2 5 Appearance 6 3 Reliability Condition 7 3 1 Temperature Condition 7 4 Recommended Connector...

Page 3: ...l Resistance top surface Toluene Tricholoroethylene Athetone Alcohol Gasoline Machine Oil Ammonia Glass Cleaner Mayonnaise Ketchup Wine Salad Oil Vinegar Lipstick etc 1 4 Mechanical Characteristics Sp...

Page 4: ...cceptable 0 4 D 0 3 1 1pcs in viewing area 1 0 3 D 0 2 2pcs in 30mm Circular Scratch Dust 0 2 D Acceptable Within 5pcs panel Applied only in the Active Area Scratches or dusts in the outside of the Ac...

Page 5: ...n by the testing rod Figure 1 Judgement Must satisfy the specification Operating Life Test Finger Condition Testing rod Refer to Figure 1 Voltage DC5V Load 3N Cycle 2 hits sec Judgement Must satisfy t...

Page 6: ...tance Test Neighboring Terminals Measured by applying the reference voltage to the terminals Active Area Electrodes Measured by applying the reference voltage to the top and bottom electrodes Judgemen...

Page 7: ...ture 60 C 3 C humidity 90 to 95 for 240 hours and in the room temperature for 2 hours Cycle Test Tested after 5 cycles of leaving the parts in the temperature 30 C 3 C for 1 hour and in the room tempe...

Page 8: ...rgent or alcohol When contaminated by chemicals wipe them off immediately with caution not to cause injury to human body The edge of the glass is not rounded and may cause injury 5 3 Construction Note...

Page 9: ...and the tail A gap must be made to absorb the tolerance in the case and the connector Tail The tail must not be forcibly stressed or bent too hard to avoid the conduction in the insulated area and wi...

Page 10: ...sfer by the user Any malfunctions and damages caused by a natural disaster or a fire Any malfunctions and damages caused by static electricity Any malfunctions and damages caused by the failure of the...

Page 11: ...000 000 hits to 10 000 000 hits 1 5 Linearity is changed Under 2 to Under 1 typical value Rev6 June 28 2004 1 3 Operating Humidity is changed Less than 90 RH no condensation to 20 C to 60 C Less than...

Page 12: ...arance specification was revised Characters of scratch dust were classified into Circular and Linear The total acceptable number of scratch dust was added 2 3 Unit of Load g changed to N to unify the...

Page 13: ...cations Rev 12 August 25 2011 1999 2010 DMC Co Ltd This document can be freely distributed but any alternation to this document is prohibited http www dmccoltd com english 9th floor Kanda Sento Buildi...

Reviews: