Step2: 

The system is installed against the wall 

 

                                 

                       

 

 

Number 

Name 

Remark 

 

Wall 

 

 

Soluna System 

 

 

Expansion Screw

 

 

 

Fixed Bracket 

 

 

Ground 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for SOLUNA S12 EU

Page 1: ...1 User Manual SOLUNA Home Storage System S12 EU DLG Energy Shanghai Co Ltd July 2019 Revision A 0 ...

Page 2: ... in this manual contact DLG Energy Shanghai Co Ltd immediately for advice and clarification The information included in this manual is accurate at the time of publication however with regards to the product design and technical specification updates our company reserves the right to make changes at any time without prior notice e In addition the illustrations in this manual are meant to help expla...

Page 3: ...nstallation tools 18 3 2 Installation spacing 20 3 3 Wire specifications 20 3 4 Installation step 20 4 How to operate Soluna 30 4 1Turn on or turn off Soluna 30 4 2 How to operate LCD 31 4 2 1 Place of LCD 31 4 2 2 How to check the information of LCD screen 32 4 2 3 How to check the informations of system 32 4 2 4 How to Set Parameter 36 5 How to maintain 40 5 1 FAN maintenance 40 5 2 Clearance 40...

Page 4: ...hall not be liable for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in the manual resulting in damage Incorrect storage installation and use Unqualified personnel install and operate the machine Failure to comply with the operation instructions and safety precautions in this manual Operate in ext...

Page 5: ...n this manual Sign Name Description Danger Serious physical injury or even death may occur if related requirements are not followed Warning Physical injury or damage to the devices may occur if related requirements are not followed Electrostatic discharge Damage may occur if related requirements are not followed Hot sides Sides of the device may become hot Do not touch Note Note Steps to take for ...

Page 6: ...nd with proper technics before operation Do not open the surface cover of the machine unless authorized The electronic components inside the machine are electrostatic sensitive Do take proper anti electrostatic measures during authorized operation Do not touch the housing of the machine or the radiator to avoid scald as they may become hot during operation The machine needs to be reliably grounded...

Page 7: ...lation tools and take mechanical protection measures to protect personal safety such as wearing smashing shoes coverall and so on Only qualified electricians are allowed to install the machine Do not put and install the machine on or close to flammable or explosive materials Do not install the machine in a place where children and other people can easily touch it To avoid a risk of electric shock ...

Page 8: ...ischarged Please follow the electrostatic protection norms and take correct protective measures because there are mostly electrostatic sensitive circuits and devices in the machine Do not use parts and components not provided by our company during maintenance Restart the machine after eliminating the faults and problems which may affect the safety and performance of the machine Do not get close to...

Page 9: ...rom the grid improves the household energy self consumption and saves the electricity cost SOLUNA integrated energy storage solve solution help users with achieving maximize the self use of green energy 2 1 Features intelligent power management Simple user controls power data history analysis and programming Capacitive touch screen interface Secure battery access door height adjustable threaded ap...

Page 10: ...10 2 3 Outline Dimensions Figure 2 1 outline dimension Width 750 mm Depth 565 mm Height 1330 mm Weight 280 kg Height Width Depth ...

Page 11: ...ional description 2 4 1 Basic principle of Soluna S12 EU Figure2 2 basic principle of Soluna S12 EU No Name Description A PV array B PV breaker C Soluna S12 EU D GRID LOAD breaker E Power meter F GRID G LOAD H APP ...

Page 12: ...er will automatically switch to EPS output when the grid if off User need to set the battery remaining value for the EPS When use the EPS function need to fit the load power rating with the EPS power rating 2 5 Technical data 2 5 1 Technical data of System System capacity Unit Nominal Storage capacity 11 52 kWh Usable Storage Capacity 10 35 kWh PV Max recommended DC power 6600 W Max DC voltage 500...

Page 13: ... phase L N PE Battery data Battery type Lithium LFP Battery capacity 225 3 75 Ah Normal voltage 51 2 VDC Voltage range 42 58 VDC Max charge current 100 A Max discharge current 100 A DOD 90 Cycle life 6000 cycle Regular parameters Dimension L W H 750 565 1330 mm Weight 280 kg Display 7 graphic LCD Communication CAN WIFI Operating temperature range 10 45 C Storage stability range 20 60 C Relative hu...

Page 14: ...5 Standard discharge Constant Current 15A end Voltage 40V 25 5 Maximum Continuous Discharge Current Constant Current 50A end Voltage 40V 25 5 Rated Capacity 75Ah Typical Capacity Range 75Ah 0 5C Charge and Discharge Impedance 25 5 60mΩ Storage Temperature Range 20 60 Charge Temperature Range 0 45 Operation Temperature Range 10 45 Delivery Capacity 30 Delivery Voltage 51 2V Cycle Life Standard Char...

Page 15: ...15 2 6 Appearance Figure 2 3 Appearance Number Name Remark Soluna bread LCD panel ...

Page 16: ...16 Figure 2 4 Appearance Number Name Remark System outlet System outlet Emergency Stop System inlet Label ...

Page 17: ...17 Figure 2 5 Appearance Number Name Remark Door lock of system Key ...

Page 18: ...18 3 Installation 3 1 Installation tools ...

Page 19: ...lation spacing around the machine during installation Position Min spacing Remark Side spacing 200cm Black spacing 10cm It needs to be installed against the wall Note For detailed requirements about the narrowest maintenance channel escape route etc refer to the applicable standards of the country region where the project is located ...

Page 20: ...the box check the following items Item Name Qty pcs Remark 1 System case 1 2 Battery module 1 3 key 2 Use to open the door of system 4 PV connector 4 5 Hexagon wrench 2 6 M8 100 Expansion screws 4 7 M8 16 Outer hexagon screw 2 8 CAN1 communication line 2 9 CAN2 communication lie 2 10 Fixed bracket 2 Use to fix system 11 Fixed bracket 1 Use to fix battery module 12 APP user manual 1 3 4 2 Basic ins...

Page 21: ...grated machine cabinet to ensure good ventilation heat dissipation installation and maintenance and safe escape There are no combustible gas and flammable materials in the installation space The installation environment shall be clean 3 4 3 Installation procedures The mechanical installation steps are as follows Step1 user can see 1unit of battery module and 1unit of the case of soluna after openi...

Page 22: ...22 Step2 The system is installed against the wall Number Name Remark Wall Soluna System Expansion Screw Fixed Bracket Ground ...

Page 23: ...23 Step3 Open the door of soluna system and open the case of battery module Figure 3 2 Number Name Remark System case Case of Battery module ...

Page 24: ...le CAN communication Remote line Number Name Remark Remote wire Battery cable CAN communication line Remark Connecting wire for communication line 1 All CAN1 lines are parallel for the internal communication of battery units 2 All CAN2 lines are parallel for the external communication between battery unit and hybrid inverter then CAN2 is connected to inverter ...

Page 25: ...25 Step 5 Fixed battery module and Close the door of Soluna system Number Name Remark M6 12 Combination screw Fixed bracket ...

Page 26: ...26 Step6 external circuit connection PV GRID LOAD Figure3 4 external circuit connection Number Name Remark Load connector GRID connector PV connector ...

Page 27: ... N m Ensure that the maximum open circuit voltage of each PV string is not higher than the maximum input voltage of the energy storage integrated machine under any circumstances It is forbidden to connect the PE wire ground wire to the positive and negative poles of the PV strings otherwise it will cause damage to the energy storage integrated machine Ensure that the PV string polarity matches the...

Page 28: ...he mains and load cables Terminal crimping torque 3 6 4 6 N m Note Before connecting the AC power grid cable to the energy storage integrated machine the lightning protection and short circuit protection measures must be taken in accordance with the local electrical safety regulations The PE cable grounding cable of the machine must be reliably grounded Connect the three wires L N and PE of the si...

Page 29: ...9 Step7 Electrical connection Figure 3 5 Electrical connection Number Name Remark A PV string B PV side breaker DC 600V 20A 2P C Soluna S12 EU D AC side breaker AC250V 32A 2P E Power meter F GRID G Load ...

Page 30: ...n all the switch of Load Grid Battery Remote Turn off Open the door and turn off all the switch of Load Grid Battery Remote Please see the above pictures for the place of switch Figure 4 1 Turn on Turn off system Number Name Remark PV breaker GRID breaker LOAD breaker BATTERY breaker REMOTE switch detail ...

Page 31: ...31 4 2 How to operate LCD 4 2 1 Place of LCD Figure 5 1 LCD Number Name Remark LCD panel Note The LCD is touch screen user can touch the screen to see the information of system ...

Page 32: ...ons click each icon will see the relevant information Please see below pictures for the interface of LCD screen Figure 5 2 LCD Screen 4 2 3 How to check the informations of PV Load Power Feed in power Battery power User can see the below interfaces after clicking the icon of PV Figure 5 3 PV information Setting icon Setting icon ...

Page 33: ...4 PV information User can see the below interfaces after clicking the icon of Load Figure 5 5 Load information User can see the below interfaces after clicking the icon of Feed in power Figure 5 6 Grid information ...

Page 34: ...34 Figure 5 7 Grid information User can see the below interfaces after clicking the icon of Battery power Figure 5 8 Battery information ...

Page 35: ...w to Set Parameter Battery charging and discharging time User can set parameter after clicking the Settings icon Set parameter for Battery Figure 5 8 set parameter for battery Figure 5 9 set parameter for battery ...

Page 36: ...36 Figure 5 10 set parameter for battery Figure 5 11 set parameter for battery Figure 5 12 set parameter for battery Set parameter for GRID Figure 5 13 set parameter for Grid ...

Page 37: ...37 Set parameter for PV Figure 5 14 set parameter for PV Set parameter for the others Figure 5 15 set parameter for others Figure 5 16 set parameter for others ...

Page 38: ...n single channel selects this mode Load power priority If the battery is selected the load will use the battery power first If the power grid is selected the load will give priority to the power grid Battery grid priority If PV is selected only PV power is used to charge the battery If PV Grid is selected PV power will be given priority to charge the battery but not enough will be supplied by the ...

Page 39: ...e housing use vacuum cleaner if necessary make sure no dust and other sundries hindering the ventilation of the system Note Shut down the fan before cleaning so as to avoid personal injury and device damage caused by electric shock and fan blades rotation at high speed 5 3 Fault handling If Soluna system has any failure information shown in the table below and it has not been eliminated after rest...

Page 40: ... Eeprom error 33 Inv soft fault 34 Fan fault 35 Cmd shut down 36 Grid loss 37 Load over current 38 Battery over current 39 Battery volt high 40 Battery open 41 Quik stop 42 Pv1 over current hw 43 Pv2 over current hw 44 Bat over current hw 45 LLC over current hw 46 LLC over voltage hw 47 CAN comm error 48 Load over power 49 Extern Battery Alarm 50 Load error hw 51 Battery volt low 52 PE Fault 53 DR...

Page 41: ...41 6 Contact us If any questions please contact us DLG Energy Shanghai Co Ltd Add No 3492 Jinqian Road Shanghai China 201406 Tel 86 21 57475835 Email sales dlgenergy com Web www dlgenergy com ...

Reviews: