38
According to the price of electricity in different time periods, users can set the
corresponding time to charge and discharge from the grid.
Grid Setup:
Output power percentage---The discharge current of the battery can be changed
here.
PV Connect mode:
Independent------PV connection single channel selects this mode.
Load power priority:
If the battery is selected, the load will use the battery power first.
If the power grid is selected, the load will give priority to the power grid.
Battery grid priority:
If PV is selected, only PV power is used to charge the battery.
If PV+Grid is selected, PV power will be given priority to charge the battery, but not
enough will be supplied by the Grid.
Battery grid switch:
Select enable, the battery can discharge to the grid.