6050-065-D-2-16
24
4.2 Control Wiring
3-Wire Radio Receiver
Limited to 250 ma.
Power (24 Volt DC) and
logic output. Power is
shut off .5 sec. prior to
gate starting and remains
off while gate is opening
and in the open position.
Com
Relay
Red Open
Green Close
White Com
24 V
o
lt
Com
Com
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Telephone
Entry
Note:
All stand-alone and
telephone entry devices must
use a separate power source.
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
NC
NO
Magnetic Lock
3-Button Station
DoorKing ONLY
SW 4, switch 3 must be
ON
.
#12 - Safety
Opening Device
24 VAC
Power
Access
Device
Open
Safety
Open
#11 - Access Control
Devices
Com
Com
24 VDC @ 250 ma Max.
Coax Antenna Kit
P/N 1514-073
Antenna mounted
outside operator cover.
Important:
Controls intended for
user activation must be located at
least six (6) feet away from any
moving part of the gate and where the
user is prevented from reaching over,
under, around or through the gate to
operate the controls. Emergency
access controls only accessible by
authorized personnel (e.g., fire, police,
EMS) may be placed at any location in
the line-of-sight of the gate.
ON
12
3
45678
SW 4
ON
12345678
SW 4
ON
12345678
SW 3
Summary of Contents for Series 6050
Page 41: ...6050 065 D 2 16 37...