6050-065-D-2-16
14
Typical Monitored Reversing Edge mounted on end of gate.
Greater than 6” but less than 16”
Gate Frame (Closed)
1.9 Continued
Monitored
Reversing
Edge
Edge
Transmitter
Gate Frame (Closed)
Reversing Edge
Edge
Transmitter
Typical Reversing Edge mounted on
bottom of gate when necessary.
If the bottom of gate is greater than 6” but less than
16” above the ground
at any point in its arc of
travel
, it is recommended mounting
a reversing edge for safety.
OPTIONAL wireless transmitter can be used.
OPTIONAL wireless transmitter can be used.
Closing Gate
See page 25 for aux terminal wiring
for monitored reversing edge.
Potential
Entrapment
Area
Mointored Sensor Note:
Input is active in both directions of travel.
Potential Entrapment Area:
Installation of
MONITORED
entrapment
protection is
REQUIRED
or operator
will
NOT
function.
Reversing Edge
A monitored reversing edge (Type B2) or a monitored photo sensor (Type B1, see previous page)
MUST
be installed or operator
WILL NOT
function.
Summary of Contents for Series 6050
Page 41: ...6050 065 D 2 16 37...