User manual for meter with U/I input PD96
6
3 Technical data
Power supply voltage
(depending on version)
External fuse (required)
Power consumption
230V AC ± 10%, 50 ÷ 60 Hz
or 110V AC ± 5%, 50 ÷ 60 Hz
or 24V DC ± 15%, (not separated)
T - type, max. 2 A
max. 2.6 VA @ 230V AC and @ 110V AC
max. 4.5 VA @ 24V DC
Current input
0÷20 mA, 4÷20 mA overload protected,
maximum input current about 40 mA
Current measurement accuracy
± 0,1% @ 25°C; ± one digit (for 0÷20 mA
range)
Current input resistance
< 65 W (typical 55 W)
Voltage input
0÷5 V, 1÷5 V, 0÷10 V, 2÷10 V
Voltage measurement accuracy
± 0,1% @ 25°C; ± one digit (for 0÷10 V range)
Voltage input resistance
> 50 kW
Temperature stability
50 ppm / °C
Display range
-999 ÷ 9999, plus decimal point
Accepted prolonged input overload
20%
Outputs
relay:
0 or 2 NO, 1A/250V AC (cos j = 1)
or OC-type:
0 or 2 30mA / 30VDC / 100mW
sensors power supply U
0
:
not stabilized
, not separated from measuring
inputs,
in 230V AC and 110V AC version:
UO = 24V DC ± 3V / max. 25 mA;
in 24V DC version:
UO = US / max. 100 mA, RO
= 3
0 W,
(where US - device power supply, RO -
internal
resistance for sensor power supply output);
Communication interface
RS 485, 8N1 and 8N2, Modbus RTU,
not separated
Baud rate
1200 bit/s ÷ 115200 bit/s
Display
(depending on version)
LED, 4 digit, 20mm height, red or
LED, 4 digit, 20mm height, green
Data memory
non-volatile memory, EEPROM type