”FiLt”
this parameter sets filtration rate. It can be set to values from 0
(no filtration ) to 5 (strongest filtration
– time window about 2 sec).
”Pnt”
decimal point position. It can be set to one of:
“ 0”, “ 0.0”, “ 0.00”, “0.000”
Decimal point position is changed by
[^]
,
[v]
buttons.
“Lo C”
“Hi C”
These parameters describe the values displayed for minimum
and maximum input current. For example, if input type is set to 4-
20 mA
“Lo C”
parameter defines the value displayed when input
current is equal 4 mA, and
“Hi C”
parameter defines the value
displayed for 20 mA of input current. Available range for these
parameters: -999 ÷ 9999. Negative values can be set by entering
'-'
sign on the first position (by use of
[^]
,
[v]
buttons).
If user defined characteristic is selected
(parameter
“CHAr”
=
”USEr”
) the
parameters „
Lo C
” and „
Hi C
” are not available for modification, due to their values
are calculated from defined characteristic.
“AddP”
- this menu allow user to add single point to the user defined
characteristic. After selection of this option device waits for „
X
” and
„
Y
” coordinates of new point. Modification of the coordinates is
done accordingly to numerical parameters edition.
Coordi
nate „
X
” defines the percentage ratio of input current to
selected current range. The
„
X
” range: -99,9 ÷ 199,9. Coordinate
„
Y
” defines displayed value for particular „
X
” value. The „
Y
” value
can be changed in range: -999 ÷ 9999, decimal point position
depend on
„Pnt”
parameter (menu
”inPt ”
).
•
User can not enter two points with the same value of „
X
” coordinate. If user
trays to do it,
”Err”
warning is displayed. To modify any defined point use
”EdtP”
option.
•
To distinguish
„
X
” and „
Y
” coordinates, if „
X
” coordinate is displayed an
additional decimal point on utmost right position is displayed.
•
If user defined characteristic is selected, and if number of defined points is
lower than 2 then
warning ”
Errc
” is displayed in measurement mode.