WP-2 Bubble Fog Machine
13 / 16
5.1.
Cleaning and maintenance
To avoid clogging of the machine, the machine should be cleaned after 40
hours of use.
For this purpose, 35% vinegar is mixed with 65% distilled water and the
machine is triggered 10-15 times.
The cleaning process should be done as follows:
•
Disconnect the machine from the power supply
•
Empty the tank with the bubble fluid
•
Pour the vinegar and distilled water mixture into the Bubble Fluid Tank
•
Connect the machine to the electricity
•
Install the machine in a well-ventilated place
•
Let the machine run for 5-10 minutes and make sure that the pump
does not run dry
•
Remove dust and fluid residue from the ventilation to prevent the
machine from overheating
•
Clean the machine housing with a damp cloth
•
The machine should be used at least once a month