- 13 -
(CH2):Speed
The second channel defines the rotating speed. It work together with Channel 1 for manual firing
(CH3): Ignition
CH3: Ignition
DMX Value
0-253
254-255
Firing
Wave flame machine won't ignite
Wave flame machine ignites
The third channel activates the actual ignition. If the DMX value of this channel higher than 253, the Wave flame machine will ignite.
(CH4): Opening time
CH4: Manual Firing Duration setup
DMX Value
0
1
2
3
............
254
255
Firing
Duration
Permanent
10ms
20ms
30ms
2540ms
Permanent
The fourth channel is the firing duration setup. Below formula can be used to calculate the firing duration (ms): DMX Value = t/10
(CH5): Channel 5 (CH5): Program Sequence
The fifth Channel allows to firing a preset sequence. Three DMX values can be used for one of the programmed firing sequence from above
sequence list (refer to above sequence list table). Below formula can be used to calculate firing sequence:
Sequence No.= DMX Channel Value÷3
Note:Channel 5 overrides Channel 1, 2, 3, and 4 in case the value is from 3~255.
(CH6): Channel 6 Mode
The sixth channel is the working mode of pump
When the safety lock located at TEST MODE, set DMX value between 50-200 to test the system. For safety, the device will not Pressurize.
When the safety lock located at USER MODE, the device Pressurize activated by set DMX value between 50-200. The device can only make
ignitions in Firing mode.
8
0°
115
9
15°
128
10
30°
140
11
45°
159
12
60°
177
13
75°
195
14
90°
213
15
105°
249
CH2: Speed Setup
DMX Value
0
1-254
255
Speed
Max Speed
Incremental of Speed
Max Speed
CH5: Sequence List
DMX Value
0~2
3~5
6~7
8~10
11~12
..........
255
Sequence No.
N/A
1
2
3
4
85