djpower FLAME MACHINE HF-210 User Manual Download Page 11

 

- 10 - 

5.4.5.

 

 Control of  Flamer 

HF-210 has 80 preset sequences, operator  can use related channel DMX value or sequence No. to access certain sequence. Below is the 
sequence list and single ignitions. 

Single Ignition Sequence List: 

 No. 

 Ignition angle 

 Description 

Nozzle 

Movement 

Firing Duration 

(For reference) 

FirinDuration (For 

reference) 

Duration (For 

reference) 

Duration (For 

reference) 

CH5 DMX 

Reference Value 

-105° 

Single Ignition SHORT flame 

Static 

0.19s 

3-5 

-90° 

Single Ignition SHORT flame 

Static 

0.19s 

6-8 

-75° 

Single Ignition SHORT flame 

Static 

0.19s 

9-11 

-60° 

Single Ignition SHORT flame 

Static 

0.19s 

12-14 

-45° 

Single Ignition SHORT flame 

Static 

0.19s 

15-17 

-30° 

Single Ignition SHORT flame 

Static 

0.19s 

18-20 

-15° 

Single Ignition SHORT flame 

Static 

0.19s 

21-23 

0° 

Single Ignition SHORT flame 

Static 

0.19s 

24-26 

15° 

Single Ignition SHORT flame 

Static 

0.19s 

27-29 

10 

30° 

Single Ignition SHORT flame 

Static 

0.19s 

30-32 

11 

45° 

Single Ignition SHORT flame 

Static 

0.19s 

33-35 

12 

60° 

Single Ignition SHORT flame 

Static 

0.19s 

36-38 

13 

75° 

Single Ignition SHORT flame 

Static 

0.19s 

39-41 

14 

90° 

Single Ignition SHORT flame 

Static 

0.19s 

42-44 

15 

105° 

Single Ignition SHORT flame 

Static 

0.19s 

45-47 

16 

-105° 

Single Ignition SHORT flame 

Static 

0.56s 

48-50 

17 

-90° 

Single Ignition SHORT flame 

Static 

0.56s 

51-53 

18 

-75° 

Single Ignition SHORT flame 

Static 

0.56s 

54-56 

19 

-60° 

Single Ignition SHORT flame 

Static 

0.56s 

57-59 

20 

-45° 

Single Ignition SHORT flame 

Static 

0.56s 

60-62 

21 

-30° 

Single Ignition SHORT flame 

Static 

0.56s 

63-65 

22 

-15° 

Single Ignition SHORT flame 

Static 

0.56s 

66-68 

23 

0° 

Single Ignition SHORT flame 

Static 

0.56s 

69-71 

24 

15° 

Single Ignition SHORT flame 

Static 

0.56s 

72-74 

25 

30° 

Single Ignition SHORT flame 

Static 

0.56s 

75-77 

26 

45° 

Single Ignition SHORT flame 

Static 

0.56s 

78-80 

27 

60° 

Single Ignition SHORT flame 

Static 

0.56s 

81-83 

28 

75° 

Single Ignition SHORT flame 

Static 

0.56s 

84-86 

29 

90° 

Single Ignition SHORT flame 

Static 

0.56s 

87-89 

30 

105° 

Single Ignition SHORT flame 

Static 

0.56s 

90-92 

 

Step Sequences List: 

No. 

Ignition angle NO. 

Description 

Nozzle 

movement 

Firing Duration 

(For reference) 

CH5 DMX 

Reference Value 

31 

Step from 1-15 

SHORT flame Step sequence 

L -> R 

2.57 s 

93-95 

32 

Step from 15-1 

SHORT flame 

R -> L 

2.57 s 

96-98 

33 

Step 5>8>11 

SHORT flame 

L -> R 

1.00 s 

99-101 

34 

Step 11>8>5 

SHORT flame 

R -> L 

1.00 s 

102-104 

35 

Step  6>10 

SHORT flame 

L -> R 

0.9 s 

105-107 

36 

Step  10>6 

SHORT flame 

R -> L 

0.9 s 

108-110 

37 

Step  4>6>8>10>12 

SHORT flame 

L -> R 

1.30 s 

111-113 

38 

Step  12>10>8>6>4 

SHORT flame 

R -> L 

1.30 s 

114-116 

39 

Step  8>6>10>4>12 

SHORT flame 

M>L>R>L
>R 

1.35 s 

117-119 

40 

Step 8>10>6>12>4 

SHORT flame 

M>R>L>R
>L 

1.35 s 

120-122 

41 

Step  1-15 

LONG flame Step sequence 

L -> R 

8.90 s 

123-125 

42 

Step  15-1 

LONG flame 

R -> L 

8.90 s 

126-128 

43 

Step  5>8>11 

LONG flame 

L -> R 

2.01 s 

129-131 

44 

Step  11>8>5 

LONG flame 

R -> L 

2.01 s 

132-134 

Summary of Contents for FLAME MACHINE HF-210

Page 1: ......

Page 2: ...ollow the instruction in the manual when operate flame machine HF 210 If you have any doubts please contact DJPOWER Use the HF 210 only under the rules and instructions from this manual Contact DJPOWER in case of doubts about the usage We assume that you your employees and others who use or come in contact with the machine are familiar with how the machine should be handled This includes proper us...

Page 3: ... the machine before operation and keep a safe distance between the person and the equipment The Safe distance for the HF 210 is at least 15m in all projection directions at least 5m to the other sides of the device Before connect the power cable communication DMX cable should well connected and ensure the command keep at firing OFF status And safety lock stay at test mode The operator responsible ...

Page 4: ...ght burst swing flame etc It is suitable for all kinds of shows to create excellent atmosphere 2 2 Features Fitted with dual valves pumps safer and more stable Fast and precise flame burst With tilt sensor design output is auto off when tilts to 45 in any direction Unique safety lock to avoid false triggering Rainproof design for the fuel nozzle thicken and anti rust metal structure durable in use...

Page 5: ...l panel Wireless Control Wire Control Maximum Output Height Appr 8 10 meters no wind condition Effect Angles 210 150 Fluid Consumption Rate Appr 0 48 min L Consumable Isopropyl alcohol Bio Ethanol Isopar G It is a must to add 10 20ML castor oil to every 10L of fuel to protect the pump from being damaged Machine Net Weight 28 kg Flightcase Net Weight 8 kg Gross Weight 40 kg Machine Dimensions 588 3...

Page 6: ...e Blue AC Ground Green Yellow Green Yellow 4 3 Resetting the Breaker This product is equipped with a resettable breaker If the breaker trips all sections of this product will lose power Remove the power cord from mains power Reset the breaker by pressing the button with your finger Plug the product s power cord into the power outlet and continue using as recommended 5 OPERATION 5 1 Preparing for O...

Page 7: ...to the standby page 5 3 2 Menu Map 显示屏 描述 参数范围 Starting Page HF 210 REV1 0 AC 230V 50Hz Initializing P 0 V 12 When the external trigger function is ON showing this page Standby Page Wait To Connect P 0 V 12 When the external trigger function is OFF to connect to DMX control showing this page Working Status Page DMX address 1 P 0 V 12 Under DMX control showing the DMX address setting Ready To Work ...

Page 8: ...t No fuel pump failure pipeline problem etc E2 Tip Err P 0 V 12 The machine tilts over 45 it stops running system will report E6 E3 Bat Err P 0 V 12 Machine stops running due to battery voltage higher than15V or lower than 10V for 5s contentiously Possible fault the battery is low E4 System Lock P 0 V 12 Safety lock located at TEST MODE E5 Relief Err P 0 V 12 Pressure relief error due to pipeline ...

Page 9: ...all be away from the danger area 3 Fueling Take out the flame fluid can and add fuel carefully put it back into the cabinet to avoid spilling ensure that the tube is placed in the fluid can tighten the container cap Please use the designated suitable fuels 4 Power and DMX cable connection Two power supplies are available for selection 1 110V 220V main power supply 2 12V battery power supply 5 Sett...

Page 10: ...able objects are within the danger area 12 Pressurize Under DMX control Channel 6 50 200 13 Firing Under DMX control Channel 3 255 14 Pressure Relief Relief pressure when show finished or Wave flame machine will not be used for a long period Under DMX control Channel 6 0 49 or 201 255 15 Switch safety lock to TEST MODE Guarantee safety use for next time 16 Power off Power off Wave flame machine te...

Page 11: ...ngle Ignition SHORT flame Static 0 56s 54 56 19 60 Single Ignition SHORT flame Static 0 56s 57 59 20 45 Single Ignition SHORT flame Static 0 56s 60 62 21 30 Single Ignition SHORT flame Static 0 56s 63 65 22 15 Single Ignition SHORT flame Static 0 56s 66 68 23 0 Single Ignition SHORT flame Static 0 56s 69 71 24 15 Single Ignition SHORT flame Static 0 56s 72 74 25 30 Single Ignition SHORT flame Stat...

Page 12: ... sequence M L 1 12 s 180 182 61 Wave 5 8 SHORT wave sequence L M 1 24 s 183 185 62 Wave 11 8 SHORT wave sequence R M 1 24 s 186 188 63 Step 2 14 SHORT flame Step sequence L R 2 16 s 189 191 64 Step 14 2 SHORT flame Step sequence R L 2 16 s 192 194 65 Step 2 14 LONG flame Step sequence L R 7 62 s 195 197 66 Step 14 2 LONG flame Step sequence R L 7 62s 198 200 67 Step 8 14 SHORT flame Step sequence ...

Page 13: ...top 5 4 6 1 About Channel 1 The first channel controls the firing angle It defines to which angle the nozzle of Wave flame machine move to The angle can be chosen anywhere between 105 to 105 DMX value 0 to 255 2 The DMX value for angle of 0 is 127 5 round up 128 Use this value following formula can be used to calculate all other angles in degree Please always note the prefix of the angle DMX Value...

Page 14: ...quence Three DMX values can be used for one of the programmed firing sequence from above sequence list refer to above sequence list table Below formula can be used to calculate firing sequence Sequence No DMX Channel Value 3 Note Channel 5 overrides Channel 1 2 3 and 4 in case the value is from 3 255 CH6 Channel 6 Mode The sixth channel is the working mode of pump When the safety lock located at T...

Page 15: ...ing mode 50 200 4 Firing Nozzle will firing and make movement from start point to end point Note After firing The DMX value of CH3 must back to 0 before an ignition can be made again Make sure CH 5 0 2 3 Example of firing with fixed duration 1 Set nozzle straight up CH1 Angle 128 CH2 Speed 0 CH3 Ignition 0 CH4 Opening time 0 CH5 Program sequence 0 CH6 Firing mode 50 200 2 Set firing duration 1s CH...

Page 16: ......

Reviews: