SZU06C1 Product Manual
SZU06C1 PM(Rev 1.0)
13
6.2
Recommended operating conditions
Parameter
Min value
Typical value Max value Unit
Environment
Supply voltage
2.1
3.3
3.9
V
RF input power
-
-
10
dbm
RF frequency
2405
2480
MHz
Operating temperature
-40
25
85
℃
-
Relative humidity
-
-
95
%
Table 6-3 Recommended Operating Conditions
7
DC Electrical Characteristics
V
3.3V,T
25
2400MHz 2483.5MHz.
DD
OP
C
f
℃,
Parameter
Test condition
Symbol
Value
Min.
Type
Max.
Supply Voltage
V
D D
2.1V
3.3V
3.9V
Supply Current
I
VDD
-
-
200mA
Reset
I
reset
2.1mA
3mA
Hard reset
reset
t
1ms
FLASH
FLSH erase
C
erase
10000
-
-
Flash data retention
t
r e te n tio n
10years
-
-
Page erase
t
erase
20ms
40ms
I
r e a d
-
-
3mA
Write operation
I
w rite
-
-
3mA
RX Current
Receive enable
I
R X
-
13.7mA
14.2mA
TX Current
TX power = 0dBm
I
TX
-
17mA
19mA
TX power = 3dBm
-
23.7mA
24mA
TX power = 8dBm
-
35.5mA
37mA
TX power = 16.5dBm
-
88.4mA
90mA
TX power = 19.5dBm
-
139mA
142mA
Sleep Current
Enter EM2 mode
I
sleep
-
3.0μA
3.2μA
Enter EM3 mode
-
1.7μA
-