background image

  FloTech Thermo-Optic Sensors and Thermistor Dummy 

 
 
 
 
 
 

 

 

 

 

Retain Sensor 

 
FloTech model FT152 is designed to fit into a ½ NPT half coupling 
welded into the bottom of each compartment.  The mounting location 
should be the lowest point of the tank.  The collar should not protrude 
more than ¾ inch outside the tank and flush with the inside of the 
tank when possible.  FloTech supplies a ½ NPT weld coupling with 
each sensor.  The coupling requires a 1 1/8" diameter hole cut in the 
bottom of the tank. After the welded coupling has cooled, install the 
sensor using pipe sealant or Teflon tape to lubricate and seal the 
threads.  Check thread engagement to ensure the retain sensor 
prism tip is set deep enough into the tank as to clear weld collar. 
 
DO NOT USE THE BODY OF THE SENSOR TO TIGHTEN! 
 
 

Dixon Bayco Warranty 

 

For complete warranty information, please refer to the latest 

 Dixon catalog. 

THERMO-OPTIC SENSORS                   Rev: Dec 2008                                 5 