REV E 3/25/20
877.582.3569
11
FT7000, RACK MONITOR MANUAL 11033PA-ATEX
3.
Remove the twelve lid screws, then open the lid. Ensure that the rubber gasket remains in
position.
4.
With the lid open, have another person lift the monitor into position in front of the drilled holes.
5.
Insert the four carriage/lag bolts into the four mounting holes shown below. If using carriage
bolts, thread the nuts onto the back of each bolt before releasing the monitor.
WARNING – WHEN CLOSING THE LID, ENSURE THAT NO WIRES ARE CAUGHT IN THE JOINT.
TIGHTENING THE LID WHILE WIRES ARE IN THE FLAME PATH MAY IMPAIR SAFETY OR DAMAGE
THE WIRES.
6.
Tighten all the screws and ensure that the monitor is secure.
7.
Do not close the lid until completing the electrical and configuration sections below.
8.
Once electrical installation and configuration are complete, close lid then install all 12 lid screws.
Hand tighten the screws then torque all screws to the ‘LID SCREW TORQUE’ specified in