9
1.Panel function
Front part
Description
LCD display main menu
1. Battery status on upper left
2. Lock status on upper middle
3. Connection status on upper right
4. Screwdriver and settings status at bottom (3 digits/letters)
Remark:
1. If NS set as [Y], NS will be shown when tightening error occurred.
2. If AS set as [Y], AS will be shown at next start when lock is triggered.
3 digits at bottom displays screw list and
counting number.
1.First digits displays current working screw
list from [1]-[9]
2.Second and third digits display current
screw count. [99]-[01]
Setting status
1. Forward rotation [FrD]
2. OK tightening [OK]
3. No ok tightening [NOK]
4. Batch complete [OK A]
5. Reverse rotation [REV]
6. Brake by forward/reverse
switch [BrK]
7. Auto Learning [Lrn]
8. Online mode [Cnt]
9. Off line mode [Dis]
9. Error code [Exx] xx : 00-99
Program Setting
Screw List –----------------(SL) Screw List
Screw Count----------------(SC) Screw Count
OKAll alarm time----------(At) OKALL Alarm time when batch complete
Slow Start Time------------(RC) Slow Start Time
Speed Level ----------------(SP) Slow Start Speed (Full speed activated when slow
start time reached)
Max Fasten Thread---------(HC)Hi Thread (max. no. of fastening threads)
Min Fasten Thread----------(LC)Low Thread (min. no. of fastening threads)
Max Fasten Time-----------(Ht) Max. fastening time
Min Fasten Time------------(Lt) Min. fastening time
Local(In-place) shutoff-----(LS) To judge double hit
NG stop-----------------------(NS) Whether to lock the screwdriver or not when
error occurred
OK ALL stop----------------(AS) Whether to lock the screwdriver or not when a
batch complete
Gear Box Ratio--------------(GR) Gear ratio
POWER LED
(Red LED on bottom)
Red LED on when low voltage
LED_OK
(Greed LED on top)
Green light on when a tightening correctly completed
LED_NOK
(Red LED on top)
Red light on when tightening time is higher or lower than max. and min fastening
time settings.
LED_OK ALL
(Green LED on top)
Greenlight on when 1 screw tightening complete or 1 batch complete.
KEY LOCK
To lock, turn the key clock wise, then operator cannot enter program setting menu.
LCD display will show a locked icon.