Symptom:
PRODUCT HOT
Possible Cause:
Compressor starts but will not keep running.
WHAT TO CHECK
SOLUTION
1. Is the temperature control knob set on its highest setting?
2. Domestically, is the voltage supply /- 10% of rating on serial plate?
3. Is the condenser clear of obstruction?
4. Is the condenser fan blade turning?
5. Is the condenser fan motor operational?
6. Is the temperature control operational?
7. Is the tube from the compressor to condenser free of kinks?
8. Is the capillary tube free of kinks?
9. Is the thermal overload operational?
10. Is the start relay operational?
11. If all of the above steps fail.....
1. YES
, see step 2.
NO,
adjust the knob to a higher setting.
2. YES
, see step 3.
NO,
consult the power company.
3. YES,
see step 4.
NO,
clear or clean.
4. YES,
see step 5.
NO,
free the obstruction or replace the blade if
needed.
5. YES,
see step 6.
NO,
replace.
6. YES,
see step 7.
NO,
replace.
7. YES,
see step 8.
NO,
repair or replace.
8. YES,
see step 9.
NO,
replace.
9. YES,
see step 10
NO,
replace.
10. YES,
see step 11.
NO,
replace.
11. Consult the Dixie-Narco Factory Service
1-800-688-9090.
Note: Have the vender Model & Serial
number available.