Installing and Operating Instructions 

1592026000 

 

1592026000 XW20K GB R1.0 22.02.2008.doc 

                       

XW20K 

4/5 

 

fins in the coldest place, where most ice is formed, far from heaters or from the warmest place during 

defrost, to prevent premature defrost termination. 

10.  TTL/RS485 Serial line 

The TTL connector allows, by means of the external module TTL/RS485 

(XJ485CX)

, to connect the 

unit to a network line 

ModBUS-RTU

 compatible as the 

dIXEL 

monitoring system XJ500 (Version 

3.0). The same TTL connector is used to upload and download the parameter list of the “

HOT KEY

“. 

The instruments can be ordered wit the serial output RS485(Optional). 

11.  Use of the programming “HOT KEY “ 

The Wing units can UPLOAD or DOWNLOAD the parameter list from its own E2 internal memory to 

the 

“Hot Key” 

and vice-versa. 

11.1

 

DOWNLOAD (FROM THE “HOT KEY” TO THE INSTRUMENT) 

1.

 

Turn OFF the instrument by means of the ON/OFF key, remove the TTL serial cable if present, 

insert the 

“Hot Key” 

and then turn the Wing ON. 

2.

 

Automatically the parameter list of the 

“Hot Key”

 is downloaded into the Wing memory, the 

DoL

” message is blinking. After 10 seconds the instrument will restart working with the new 

parameters. 

3.

 

Turn OFF the instrument remove the 

“Hot Key”, 

plug in  the TTL serial cable, then turn it ON 

again. 

At the end of the data transfer phase the instrument displays the following messages: 

 

end

 “ for right programming.  

 

The instrument starts regularly with the new programming. 

 

err

” for failed programming.  

In this case turn the unit off and then on if you want to restart the download again or remove 

the “

Hot key

” to abort the operation. 

11.2

 

UPLOAD (FROM THE INSTRUMENT TO THE “HOT KEY”) 

1.

 

Turn OFF the instrument by means of the ON/OFF key and remove the TTL serial cable if 

present; then turn it ON again. 

2.

 

When the Wing unit  is ON, insert the “

Hot key

” and push 

o

 

key; the  

"uPL" 

message 

appears. 

3.

 

Push “

SET”

 key to start the UPLOAD; the “

uPL

” message is blinking. 

4.

 

Turn OFF the instrument remove the 

“Hot Key”, 

plug in  the TTL serial cable, then turn it ON 

again. 

At the end of the data transfer phase the instrument displays the following messages: 

 

end

 “ for right programming. 

err

” for failed programming. In this case push “SET” key if you want to restart the 

programming again or remove the not programmed “

Hot key

”. 

12. ALARM SIGNALS 

Message  Cause 

Outputs 

“P1” 

Thermostat probe failure 

Alarm output ON; Compressor output according to 

parameters “COn” and “COF” 

“P3” 

Probe 3 probe failure 

Alarm output ON; Other outputs unchanged 

“P4” 

Probe 4 probe failure 

Alarm output ON; Other outputs unchanged 

“HA” 

Maximum temperature alarm 

Alarm output ON; Other outputs unchanged 

“LA” 

Minimum temperature alarm 

Alarm output ON; Other outputs unchanged 

"HA2"  Condenser high temperature 

It depends on the “Ac2” parameter 

"LA2"  Condenser low temperature 

It depends on the “bLL” parameter 

“dA” 

Door open 

Compressor and fans restarts  

“EA” 

External alarm 

Output unchanged. 

“CA” 

Serious external alarm (i1F=bAL)  All outputs OFF. 

“CA” 

Pressure switch alarm (i1F=PAL)  All outputs OFF 

“EE” 

Data or memory failure 

Alarm output ON; Other outputs unchanged 

The alarm message is displayed until the alarm condition is recovery. 

All the alarm messages are showed alternating with the room temperature except for the “P1” which is 

flashing. 

To reset the “EE” alarm and restart the normal functioning press any key, the “

rSt

” message is 

displayed for about 3s. 

12.1

 

SILENCING BUZZER  

Once the alarm signal is detected the buzzer can be silenced by pressing any key. Buzzer is mounted 

in the keyboard and it is an option. 

12.2

 

“EE” ALARM 

The 

dIXEL

 instruments are provided with an internal check for the data integrity. Alarm “EE” flashes 

when a failure in the memory data occurs. In such cases the alarm output is enabled. 

12.3

 

ALARM RECOVERY 

Probe alarms : “

P1

” (probe1 faulty), “

P3

” and 

“P4”

; they automatically stop 10s after the probe restarts 

normal operation. Check connections before replacing the probe. 

Temperature alarms “

HA

”, “

LA

” “

HA2

” and “

LA2

” automatically stop as soon as the temperature 

returns to normal values. 

Alarms 

“EA”

 and 

“CA” 

(with i1F=bAL)

 

recover as soon as the digital input is disabled. 

Alarm “

CA”

 (with i1F=PAL) recovers only by 

switching off and on

 the instrument. 

 

13. Technical data 

Keyboards 

Housing: 

self extinguishing ABS.

 

Case: T620: 

facia 38x185 mm; depth 23mm 

 V620: 

facia 72x56 mm; depth 23mm 

 CX620: 

facia 75x36 mm; depth 23mm 

Mounting:

 

T620: 

panel mounting in a 150x31 mm panel cut-out with two screws. 

 3 x 2mm. 

Distance between the holes 165mm 

V620: 

panel mounting in a 56x72 mm panel cut-out with two screws. 

 3x2mm. Distance 

between the holes 40mm 

 CX620: 

panel mounting in a 71x29mm panel cut-out 

Protection: 

IP20; 

Frontal protection:

 IP65 with frontal gasket 

Connections: 

Screw terminal block 

 2,5 mm

2

  

Power supply: 

from

 XW20K 

power module

 

Display

: 3 digits, red LED, 14,2 mm high.  

Optional

 output: buzzer

 

Power module XW20K  

Case: 8 DN:

 140X176X148. 

Connections: 

Screw terminal block 

 2,5 mm

2

 heat-resistant wiring and 6,3mm Faston 

Power supply: 

230Vac or. 110Vac 

±

 10% or 24Vac

 

Power absorption: 

10VA max.

 

Inputs

: 4 NTC probes 

Digital inputs

: 1 free voltage 

Relay outputs: 

Total current on loads MAX. 20A

 

compressor:

 relay SPST 20(8) A, 250Vac  

 light 

(oA3):

 relay SPST 16(5) A, 250Vac 

Serial output :

 TTL standard.  

Communication protocol:

 Modbus - RTU

 

Data storing

: on the non-volatile memory (EEPROM). 

Kind of action: 

1B. 

Pollution grade: 

normal 

Software class: 

A.

 

Operating temperature: 

0÷60 °C. 

Storage temperature: 

-25÷60 °C.  

Relative humidity:

 20

÷

85% (no condensing) 

Measuring and regulation range: NTC probe: 

-40÷110°C (-58÷230°F) 

Resolution: 

0,1 °C or 1°C or 1 °F (selectable). 

Accuracy (ambient temp. 25°C)

:  ±0,5 °C ±1 digit 

14. CONNECTIONS 

14.1

 

XW20K 

 

 

15.  Default setting values 

 

Label  Name 

  Range 

Default  Level

 REGULATION 

 

 

 

Set 

Set point 

LS÷US 

3.0 - 

Hy 

Differential 

0,1÷25,5 °C / 1÷45°F 

2.0 Pr1 

LS 

Minimum set point 

 -50,0°C÷SET / -58°F÷SET 

-50.0 Pr2 

US 

Maximum set point 

SET ÷ 110°C / SET ÷ 230°F 

110 Pr2 

Ot 

Thermostat probe calibration 

-12

÷

12°C /-120

÷

120°F 

0.0 Pr1 

P3P 

Third probe presence (1st cond. 

probe) 

n=not present; Y=pres. 

n Pr2 

O3 

Third probe calibration 

-12

÷

12°C /-120

÷

120°F 

0 Pr2 

P4P 

Fourth probe presence (2nd  cond. 

probe) 

n=not present; Y=pres. 

n Pr2 

O4 

Fourth probe calibration 

-12

÷

12°C /-120

÷

120°F 

0 Pr2 

OdS 

Outputs activation delay at start up 

0÷255 min. 

0 Pr2 

AC 

Anti-short cycle delay 

0÷30 min. 

1 Pr1 

Ac1 

Second compressor delay 

0÷255s 

5 Pr2 

CCt 

Compressor ON time during fast 

freezing 

0 ÷ 23h 50 min. 

0.0 Pr2 

CCS 

Set point for continuous cycle 

 (-55.0÷150,0°C) 

3 Pr2 

COn 

Compressor ON time with faulty probe 

0÷255 min. 

15 Pr2 

COF 

Compressor OFF time with faulty 

probe 

0÷255 min. 

30 Pr2 

CH 

Kind of action 

CL=cooling; Ht= heating 

cL Pr1 

 DISPLAY 

 

 

CF 

Temperature measurement unit 

°C ÷ °F 

°C  

Pr2 

rES 

Resolution (integer/decimal point) 

in ÷ de 

dE  

Pr1 

rEd 

Remote display  

P1 ÷ 1r2 

P1 Pr2 

dLy 

Display temperature delay   

0 ÷ 20.0 min  (10 sec.)  

0 Pr2 

 DEFROST 

 

 

dFP 

Probe selection for defrost termination 

nP; P1; P2; P3; P4 

nP Pr2 

dtE 

Defrost termination temperature  

-50,0÷110°C / -58÷230°F 

0 Pr2 

IdF 

Interval between defrost cycles 

1÷120h 

8 Pr1 

MdF 

(Maximum) length for 1° defrost 

0÷255 min. 

20 Pr1 

dFd 

Displaying during defrost 

rt, it, SEt, dEF, dEG 

it Pr2 

dAd 

MAX display delay after defrost 

0÷255 min. 

30 Pr2 

 AUXILIARY 

THERMOSTAT

 

 

 

 

ACH 

Kind of action for auxiliary relay  

CL; Ht 

cL Pr2 

SAA 

Set Point for auxiliary relay 

-50,0÷110°C /  -58÷230°F 

0,0 Pr2 

SHy 

Differential for auxiliary relay 

0,1÷25,5 °C / 1÷45°F 

2,0 Pr2 

ArP 

Probe selection for auxiliary relay 

nP / P1 / P2 / P3 

nP Pr2 

Sdd 

Aux.output working during defrost 

n, y 

n Pr2 

 ALARMS 

 

 

Summary of Contents for CX620

Page 1: ...e terminated before the end of the set time using the same activation key o for 3 seconds DEFROST Defrost is performed through a simple stop of the compressor Parameter IdF controls the interval between defrost cycles while its length is controlled by parameter MdF 3 3 DEFROST Defrost is performed through a simple stop of the compressor The parameters involved are to control the interval between d...

Page 2: ...OFF for 5 sec and the ON OFF LED is switched ON During the OFF status all the relays are switched OFF and the regulations are stopped if a monitoring system is connected it does not record the instrument data and alarms When the instrument is in stand by the keyboard displays oFF N B During the OFF status the Light and AUX buttons are active 5 11 TO SEE THE PROBE VALUES 1 Enter in Pr1 level 2 Para...

Page 3: ...cycle 30 0 C 30 0 C 22 86 F it sets the increasing value of the set point during the Energy Saving cycle OTHER Adr RS485 serial address 1 247 Identifies the instrument address when connected to a ModBUS compatible monitoring system PbC Type of probe it allows to set the kind of probe used by the instrument PbC PBC probe ntc NTC probe onF on off key enabling nu disabled oFF enabled ES to start a en...

Page 4: ...y Alarm EE flashes when a failure in the memory data occurs In such cases the alarm output is enabled 12 3 ALARM RECOVERY Probe alarms P1 probe1 faulty P3 and P4 they automatically stop 10s after the probe restarts normal operation Check connections before replacing the probe Temperature alarms HA LA HA2 and LA2 automatically stop as soon as the temperature returns to normal values Alarms EA and C...

Page 5: ...alarm n 0 Y 1 n Pr2 AC2 Compr off for condenser high temperature alarm n 0 Y 1 n Pr2 AUXILIARY OUTPUT tbA Alarm relay disabling n no y yes y Pr2 oA3 Fourth relay configuration ALr alarm dEF do not select it Lig Light AUS AUX onF always on Fan do not select it db do not select it dF2 do not select it Lig Pr2 AoP Alarm relay polarity oA3 ALr oP cL cL Pr2 DIGITAL INPUT i1P Digital input polarity oP o...

Reviews: