HEATING RELAY SAFETY (i1F=Ht)
With
i1F=Ht
as soon as the digital input is activated for “
did
” time heating relay is disabled.
The alarm will stop as soon as the digital input is de-activated.
10.6
DIGITAL INPUTS POLARITY
The digital input polarity depends on the “
i1P
” parameters.
CL
: the digital input is activated by closing the contact;
OP
: the digital input is activated
by opening the contact
11.
INSTALLATION AND MOUNTING
The temperature range allowed for correct operation is 0 - 60 °C. Avoid places subject to strong vibrations, corrosive gases, excessive dirt or
humidity. The same recommendations apply to probes. Let the air circulate by the cooling holes.