Thank you for the purchase of this DiversiTech condensate pump.  This 
pump is designed to automatically remove the condensate water that 
collects from appliances such as air conditioners, high-efficiency furnaces 
and de-humidifiers.   

The pump has a built-in tank that collects the water from the appliance.   
When the water collected reaches sufficient level inside the pump tank, 
the pump switches on and pumps the water to a remote location for 
disposal. When the tank is sufficiently empty the pump automatically 
switches off.  

The pump is capable of lifting water to its rated height and is equipped 
with a check valve that prevents water from flowing back into the tank 
when the pump shuts off.   

The pump is outfitted with lights that show the status of power available, 
motor running and high water (alarm) conditions.  

The pump is also equipped with a switch that activates when the water in 
the tank reaches an overflow condition.  The overflow safety switch may 
be connected to turn off the appliance if the high water condition occurs.  
The switch also has an alarm terminal that may optionally be connected to 
an audible alarm or remote indicator light to indicate a trouble condition.

Pump should be stored indoors.  
The chosen location should be clean and dry.

 

Carefully open the carton to avoid damage to the pump.  Do not use a 
knife or other sharp object that may scratch the pump’s cover.  After 
opening the carton, look for damage.  If damage is found file a claim with 
the freight carrier.

CAUTION: Be sure to remove the cardboard insert.  It is used to protect the 
float during shipment.  Failure to remove the insert will cause the pump to 
run continuously.

Supply voltage and frequency must match what is shown on the pump 
nameplate.  Source voltages lower than the rated supply can reduce 
performance and cause the pump to overheat.

 
The pump must be level and should be placed on a solid surface or floor.  
The pump has rubber feet to reduce noise and keep it in place during 
operation.

Do not use this pump in the presence of spraying or standing water, it may 
cause a shock.  This pump is not suitable for use in Class I or Class II loca-
tions (explosive gas or dust).

Do not cover the pump air vents.  The pump is air cooled.   Do not cover 
the vent holes located on the top or sides of the pump housing.  The pump 
may be operated continuously as long as the air vents are not covered. 

General Information

Unpacking

Power Source

Pump Installation

CHECK FOR 

SHIPMENT 

DAMAGE

Summary of Contents for CP-22

Page 1: ...Installation and Safety Instructions Condensate Pump CP 22 CP 22 230 CP 22LP CP 22LP 230 ...

Page 2: ...Shutoff Leads with Insulated Terminals Polyethelene Inlet Covers 3 Black Live Hot White Neutral Green Ground All installations must conform to NEC requirements 220 Volts 60 Hz 208 230 1 0 Amps NEMA 6 15 plug 22 ft maximum 1 6 GPM Continuous duty 140F Max inlet temperature 160F Not suitable for contact with steam or gasses that exceed 160F 11 8 x 5 9 x 6 7 4 9 H low profile 5 lbs 4 7 lbs low profil...

Page 3: ...r warranties that extend beyond the description of the face hereof The liability of the Company arising out of it s supply of said products or their use shall not in any case exceed the cost of correcting defects in the products as set forth above The Company shall not be liable for any costs or damage incurred by its customers in the removal or replacement of defective products from units in whic...

Page 4: ...remote indicator light to indicate a trouble condition Pump should be stored indoors The chosen location should be clean and dry Carefully open the carton to avoid damage to the pump Do not use a knife or other sharp object that may scratch the pump s cover After opening the carton look for damage If damage is found file a claim with the freight carrier CAUTION Be sure to remove the cardboard inse...

Page 5: ...ks the flow of air from the AC unit which is wasteful and can cause other prob lems such as accelerated algae growth The pump is equipped with a combination barb type fitting and check valve The fitting allows the connection of 3 8 flexible vinyl tubing such as DiversiTech CVT clear vinyl Attach the tubing by pressing it over the barb fitting and secure with a screw type hose clamp Route the tubin...

Page 6: ...Safety Switch operation if used to be sure that the A C system shuts down and the red ALARM LED lights when the pump has reached an overflow condition Leak Check Operate the pump by filling tank to trigger operation Pump RUN will be indicated by the yellow RUN LED Homeowner Instruction Instruct the homeowner about the pump s general operation how to add Pro Treat tablets and to look for the ALARM ...

Reviews: