IMPORTANT NOTICE 

WARRANTY

®

WHEN USING THIS THERMOSTAT WITH A GAS FURNACE 
A COMMON WIRE (C) MUST BE CONNECTED.

When working without a common wire:

A

confirm in heat mode the cooling does not switch on or 

B

confirm in cooling mode

the heat does not switch on.

If test 

A

or 

B

fail or the thermostat shuts down in either heat or cool mode then it is

necessary to connect a common wire, (C), alternatively it may be possible to solve this
issue by simply connecting the 250 ohm 10 watt resistor between C and W (in the
case of a cooling problem – see B) or between C and Y1 (in the case of a heating
problem - see A) at the HVAC equipment.   

When working without a common wire, 

A

confirm that when there is a call for heat,

cooling does not also activate, and when there is a call for cool, heating does not
also activate.  

If using the configuration of 

Heat Pump and Furnace with no Common Wire

confirm that when Heat Pump and Furnace are working together (both stages
are operating at the same time) that the display does not go blank, if so you must
use a Common Wire. 

This thermostat is equipped to run with two separated power transformers if required
RC and RH.  Terminals RC and RH are internally connected together however you
should wish to use two transformers simply cut with a blade the copper trace on
the printed circuit board located between the C and Y2 screw terminals.  

Hardware

DiversiTech warrants the original end user (“Customer”) that new DiversiTech branded products will be free from defects
in workmanship and materials, under normal use, for two (2) years from the original purchase date.

Software

DiversiTech warrants to Customer that the DiversiTech thermostat software will perform in substantial conformance to
its program specifications for a period of two (2) years from the date of the original purchase.

Exclusions

This warranty excludes (1) physical damage to the surface of the product, including cracks or scratches on the touch-
screen or outside casing; (2) damage caused by misuse, neglect, improper installation, unauthorized attempts to open,
repair, or modify the product, or any other cause beyond the range of intended use; (3) damage caused by accident, fire,
power changes, other hazard, or Acts of God; or (4) use of the product with any device if such device causes the problem.

Exclusive Remedies

Should a covered defect occur during the warranty period and Customer notifies DiversiTech, Customer’s sole and exclu-
sive remedy will be, at DiversiTech’s sole option and expense, to repair or replace the product. Replacement products or
parts may be new or reconditioned or a comparable version of the defective item. DiversiTech warrants any replaced prod-
uct or part for a period of ninety (90) days from shipment, or through the end of the original warranty, whichever is longer.

Obtaining Warranty Service

Customer must contact and return product to a local DiversiTech product dealer or installer within the applicable war-
ranty period to obtain warranty service. Dated proof of original purchase will be required. DiversiTech will not be respon-
sible for Customer’s memory data contained in, stored on, or integrated with any products returned to DiversiTech for
repair, whether under warranty or not. 

Warranty Exclusive

THE FORGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, CORRESPONDENCE WITH
DESCRIPTION, AND NON-INFRINGEMENT, ALL OF WHICH ARE EXPRESSLY DISCLAIMED BY DIVERSITECH AND ITS SUPPLIERS.

Disclaimer

NEITHER DIVERSITECH NOR ITS SUPPLIERS SHALL BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL,
OR PUNITIVE DAMAGES OF ANY KIND, OR FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE OR
USE OF THIS PRODUCT, WHETHER BASED IN CONTRACT, TORT (INCLUDING NEGLIGENCE) OR ANY OTHER THEORY, EVEN
IF DIVERSITECH HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. DIVERSITECH’S ENTIRE LIABILITY SHALL
BE LIMITED TO REPLACEMENT OR REPAIR OF THE PRODUCT.

Summary of Contents for 675-TS32H

Page 1: ...www diversitech com Technical Support 1 800 995 2222 TOUCH SCREEN THERMOSTAT INSTRUCTION MANUAL 675 TS32H 3 Heating and 2 Cooling with Humidification and De humidification...

Page 2: ...on relay Independent de humidification relay Customizable full and partial lock security Adjustable differential settings for multistage installations Energy watch calculates kWh and HVAC costs Simple...

Page 3: ...MODES 18 TEMPERATURE SETPOINTS 19 HUMIDIFICATION AND DE HUMIDIFICATION SETPOINTS 20 FAN OPERATION MODES 22 MENU PAGE 23 MENU PAGE DATE AND TIME SETTINGS 24 MENU PAGE PROGRAM SETTINGS 25 MENU PAGE ENER...

Page 4: ...quipment on at 70 degrees F and turns the heating equipment off at 74 degrees F then the differential is 4 degrees F Humidifier A device used to add moisture to a space Humidistat A control which is o...

Page 5: ...electrical service panel All heating and cooling units should be OFF 2 Remove the cover plate by pulling up the cover from the left or right side only 3 Align the thermostat unit to the wall 4 Mark t...

Page 6: ...RAMS I2 1 AIR CONDITIONER 24V FAN AC I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON AC2 I2 2 AIR CONDITIONERS 24V FAN AC1 I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON HEAT I2 1 AIR CONDITIONER AND 1 HEAT 24V FAN AC I...

Page 7: ...EVALVES I2 1 HEAT PUMP AND 1 HEAT 24V FAN HP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON REVERSEVALVES I2 1 HEAT PUMP 24V FAN HP I1 RC DH H C Y2 RH OBW W2 G Y1 COMMON I2 COMMON 2 HEAT PUMPS HP2 24V REVERSEV...

Page 8: ...ERMOSTAT INSTALLATION WIRING DIAGRAMS I2 HUMIDIFIER WITHOUT TRANSFORMER 24V I1 RC DH H C Y2 RH OBW W2 G Y1 HUMIDIFIER 2nd WIRE HUMIDIFIER 1st WIRE HEAT TRANSFORMER COOL TRANSFORMER I2 2 TRANSFORMERS I...

Page 9: ...nge raise or lower set point as desired In Auto mode touch the Heat Cool button Heat or Cool will flash once selected then raise or lower set points as desired 9 Humidity Auto 10 Displays Installer Me...

Page 10: ...on your HVAC equipment you can quickly and easily select the mode of operation Automatic Heat Cool Off AUTO choose your heat and cool temperature setpoints the temperature will automatically adjust a...

Page 11: ...toring and lowering the room humidity Since the De Humidify feature uses the Cool Function of your Air Conditioner or Heat Pump your DiversiTech thermostat will turn off the air conditioning if either...

Page 12: ...STAT OPERATION MENU PAGE To access the Menu Page simply touch Menu from the Control Page Remember it is as easy as a touch of the button Set up of your DiversiTech thermostat is effortless with intuit...

Page 13: ...7 Day Programmable with 4 events per day including Fan Mode Select the Day of the Week Select the Event number for example 1 Select the Start Time for example 7 00 AM Choose desired temperature setpoi...

Page 14: ...gs it places the DiversiTech thermostat screen in a sleep mode for 15 seconds SET SCREEN Your DiversiTech thermostat has a number of options to ensure clear viewing throughout the day and night firstl...

Page 15: ...parture and ends at Midnight on the day of your arrival When the Vacation mode is active the suitcase icon will appear on the Home Page Upon your return from vacation a message Vacation Mode Ended wil...

Page 16: ...nt and to fully customize the thermostat ADVANCED SETTINGS To begin hold your finger for 5 seconds on the Advanced Settings Button you will hear a beep telling you that you are in the process of enter...

Page 17: ...inders or emergency contact information Type your message in using the keyboard upon completion choose OK Set the number of months after which you with the message to appear Touch the home or menu ico...

Page 18: ...iagram for wiring instructions CYCLE RATE Set Maximum compressor cycles per hour AUTO CHANGE Set the minimum difference between Auto Mode Heat and Cool temperature set points DIVERSITECH TOUCH SCREEN...

Page 19: ...nique function avoids excess compressor wear in the case where the necessary temperature set point is not met through setting of the Staging Differentials Set to 00 to disable DIVERSITECH TOUCH SCREEN...

Page 20: ...mes a spare relay and can be used for a variable speed fan or separate dehumidifier or air exchanger DIVERSITECH TOUCH SCREEN THERMOSTAT CONFIGURATION ADVANCED SETTINGS HUMIDIFICATION DEHUMIDIFICATION...

Page 21: ...N This method will run the compressor until the de humidification level is reached and may cause overcooling OPTION 3 Connect the DH terminal to a variable speed fan control set DH REVERSE to control...

Page 22: ...hermostat Thermostat Fahrenheit Celsius Calibration Number Change Change 3 0 6 F 3 0 C 2 5 5 F 2 5 C 2 0 4 F 2 0 C 1 5 3 F 1 5 C 1 0 2 F 1 0 C 0 5 1 F 5 C Factory Setting 00 No Correction Required 0 5...

Page 23: ...the C wire another possible solution is to connect one 250 ohm 10 watt resistor in the HVAC room for cooling problems between C and W or in the case of heating prob lem between C and Y1 I forgot my PI...

Page 24: ...luding cracks or scratches on the touch screen or outside casing 2 damage caused by misuse neglect improper installation unauthorized attempts to open repair or modify the product or any other cause b...

Page 25: ...www diversitech com Technical Support 1 800 995 2222 FCC Statement THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS 1 THIS DEVICE MAY NOT CAUSE...