5
PROCESS COUNTER
UP
counter,
DOWN
counter and bidirectional
UP/DOWN
counter
•
In
UP/ DOWN
mode it can be programmed to
work: Independent, Directional or Phase.
•
Remote and front-panel reset
•
Decimal point indication
•
Reset may load a count value (OFFSET),
programmable or entered from the display
•
Multiplier/Divider factor from 0.0001 to 99999
•
Programmable low frequency debounce filter (20
Hz) activates automatically when a contact closure
input type is selected.
•
Key-lock for RESET
TOTALIZER COUNTER
•
Selectable totalizer with separate decimal point and
scale factor independent from process counter.
•
Count display from 99999999 to -9999999.
Decimal
point position programmable.
•
Selectable 4 positions decimal point
•
Input configuration and count mode is the same as
selected for the process counter
•
Alternating display of 4 digits high order part and 4
digits low order part of the value with corresponding
indication H and L.
•
No offset possibility
•
Key-lock for the RESET function
•
Remote and front-panel reset
•
Scale factor from 0.0001 to 99999
CHRONOMETER
•
Four ranges 999,99s, 999m59s, 999h59m, 9999.9h
•
Remote and front-panel reset
•
Reset may load a count value (OFFSET), programmable
or entered from the display
•
Counts UP or DOWN
•
Key-lock for RESET
FREQUENCY METER / TACHOMETER
•
Measures frequency, rpm, rate, flow and time
.
•
Decimal point indication
•
Scale factor programmable from 0.0001 to 9999
•
Display update time programmable from 0.1 to 9.9s
•
Pulse arrival time limit programmable from 1 to 99.9s
•
MAX and MIN values memorisation (TACHOMETER)
5
PROCESS COUNTER
UP
counter,
DOWN
counter and bidirectional
UP/DOWN
counter
•
In
UP/ DOWN
mode it can be programmed to
work: Independent, Directional or Phase.
•
Remote and front-panel reset
•
Decimal point indication
•
Reset may load a count value (OFFSET),
programmable or entered from the display
•
Multiplier/Divider factor from 0.0001 to 99999
•
Programmable low frequency debounce filter (20
Hz) activates automatically when a contact closure
input type is selected.
•
Key-lock for RESET
TOTALIZER COUNTER
•
Selectable totalizer with separate decimal point and
scale factor independent from process counter.
•
Count display from 99999999 to -9999999.
Decimal
point position programmable.
•
Selectable 4 positions decimal point
•
Input configuration and count mode is the same as
selected for the process counter
•
Alternating display of 4 digits high order part and 4
digits low order part of the value with corresponding
indication H and L.
•
No offset possibility
•
Key-lock for the RESET function
•
Remote and front-panel reset
•
Scale factor from 0.0001 to 99999
CHRONOMETER
•
Four ranges 999,99s, 999m59s, 999h59m, 9999.9h
•
Remote and front-panel reset
•
Reset may load a count value (OFFSET), programmable
or entered from the display
•
Counts UP or DOWN
•
Key-lock for RESET
FREQUENCY METER / TACHOMETER
•
Measures frequency, rpm, rate, flow and time
.
•
Decimal point indication
•
Scale factor programmable from 0.0001 to 9999
•
Display update time programmable from 0.1 to 9.9s
•
Pulse arrival time limit programmable from 1 to 99.9s
•
MAX and MIN values memorisation (TACHOMETER)