Service - 110
420sx Operator’s Manual
50 Hour
Check Fan/Alternator Belt Tension
Check belt tension every 50 hours. Belt is properly tensioned when it moves about 3/8” (10 mm) when
pushed at the long span (4). To adjust belt, move tensioner pulley:
1. Loosen socket bolt (2) and bolt (1).
2. Use a prybar in slots (3) to move pulley.
3. Tighten socket bolt (2) and bolt (1).
4. Check belt tension and adjust as needed.
Change Hydraulic Fluid Filter (initial)
Change hydraulic fluid filter for the first time at 50 hours and every 500 hours thereafter.
Note:
Boltheads are hidden. Use an 8 mm hex wrench, a 17 mm open end wrench, and a 1/2” prybar for
this procedure.
Summary of Contents for 420sx
Page 1: ...420sx Operator s Manual 053 1110 Issue 3 0 CMW...
Page 8: ...420sx Operator s Manual Overview 7 Unit Components CMW Drill 1 Coupler 2 Zerk 3 U joint...
Page 11: ...Overview 10 420sx Operator s Manual About This Manual CMW...
Page 25: ...Safety 24 420sx Operator s Manual Emergency Procedures CMW...
Page 39: ...Controls 38 420sx Operator s Manual Attachment Controls CMW...
Page 43: ...Operation Overview 42 420sx Operator s Manual Leaving Jobsite CMW...
Page 63: ...Transport 62 420sx Operator s Manual Tow CMW...
Page 71: ...Plow 70 420sx Operator s Manual Operating Tips CMW...
Page 77: ...Trench 76 420sx Operator s Manual Operating Tips CMW...
Page 97: ...Service 96 420sx Operator s Manual Lubrication Overview Lubrication Overview...
Page 129: ...Service 128 420sx Operator s Manual As Needed...
Page 135: ...Specifications 134 420sx Operator s Manual 420sx...
Page 138: ......
Page 139: ......
Page 140: ...420sx Operator s Manual Service Record 139 CMW Service Record Service Performed Date Hours...
Page 141: ...CMW Service Record 140 420sx Operator s Manual Service Performed Date Hours...